id:@b-0000 dis:Bravo area:78000ft² custom:{elecFreq:60Hz} geoAddr:"123 Some Rd, Fort Wayne, IN 46900" geoCity:Fort Wayne geoCountry:US geoCounty:US geoPostalCode:"46900" geoState:IN geoStreet:"123 Some Rd" primaryFunction:"Hospital (General Medical & Surgical)" site tz:Chicago weatherStationRef:@b-042f yearBuilt:2000 --- id:@b-0001 dis:Bravo BCU-1 chilledWaterCooling custom:{tu bcu} equip hvac singleDuct siteRef:@b-0000 spaceRef:@b-000d thermostat vav zone --- id:@b-0002 dis:Bravo BCU-1 Cooling Valve Output chilled cool cur custom:{predictionConf:0.31259757180034364 sourcePointName:"ChwVlvOR_value" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0001 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-000d tz:Chicago unit:"%" valve water --- id:@b-0003 dis:Bravo BCU-1 Mixed Air Damper Output air cmd cur custom:{predictionConf:0.28394372966813813 sourcePointName:"MadOR_value" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper equipRef:@b-0001 his kind:Number mixed point siteRef:@b-0000 spaceRef:@b-000d tz:Chicago unit:"%" --- id:@b-0004 dis:Bravo BCU-1 Supply Air Temperature air cur custom:{predictionConf:0.7893816782198223 sourcePointName:"DAT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0001 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-000d temp tz:Chicago unit:°F --- id:@b-0005 dis:Bravo BCU-1 Zone Temperature air cur custom:{predictionConf:0.6720981954640639 sourcePointName:"SpaceTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0001 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-000d temp tz:Chicago unit:°F zone --- id:@b-0006 dis:Bravo BCU-1 Zone Temperature Setpoint air cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York backgroundPoint} equipRef:@b-0001 his kind:Number maxVal:327 minVal:-273 point siteRef:@b-0000 sp spaceRef:@b-000d temp tz:Chicago unit:°F zone --- id:@b-0007 dis:Bravo BCU-2 chilledWaterCooling custom:{tu bcu} equip hvac singleDuct siteRef:@b-0000 spaceRef:@b-000d thermostat vav zone --- id:@b-0008 dis:Bravo BCU-2 Cooling Valve Output chilled cool cur custom:{sourcePointName:"ChwVlvOR_value" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-0007 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-000d tz:Chicago unit:"%" valve water --- id:@b-0009 dis:Bravo BCU-2 Mixed Air Damper Output air cmd cur custom:{sourcePointName:"MadOR_value" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} damper equipRef:@b-0007 his kind:Number mixed point siteRef:@b-0000 spaceRef:@b-000d tz:Chicago unit:"%" --- id:@b-000a dis:Bravo BCU-2 Supply Air Temperature air cur custom:{sourcePointName:"DAT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0007 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-000d temp tz:Chicago unit:°F --- id:@b-000b dis:Bravo BCU-2 Zone Temperature air cur custom:{sourcePointName:"SpaceTemp" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0007 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-000d temp tz:Chicago unit:°F zone --- id:@b-000c dis:Bravo BCU-2 Zone Temperature Setpoint air cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York backgroundPoint} equipRef:@b-0007 his kind:Number maxVal:327 minVal:-273 point siteRef:@b-0000 sp spaceRef:@b-000d temp tz:Chicago unit:°F zone --- id:@b-000d dis:Bravo BCUs custom:{equipType} siteRef:@b-0000 space --- id:@b-000e dis:Bravo Boiler 1 boiler custom:{designSource:"Drawings" designHotWaterPower:4200MMBTU/h designMake:"Bryan Boiler" designModel:"RV-500W"} equip hotWaterRef:@b-0012 hvac siteRef:@b-0000 spaceRef:@b-00ab --- id:@b-000f dis:Bravo Boiler 1 Boiler Status boiler cur custom:{sourcePointName:"HwBlr1Sts" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-000e his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00ab tz:Chicago --- id:@b-0010 dis:Bravo Boiler 2 boiler custom:{designSource:"Drawings" designHotWaterPower:4200MMBTU/h designMake:"Bryan Boiler" designModel:"RV-500W"} equip hotWaterRef:@b-0012 hvac siteRef:@b-0000 spaceRef:@b-00ab --- id:@b-0011 dis:Bravo Boiler 2 Boiler Status boiler cur custom:{sourcePointName:"HwBlr2Sts" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0010 his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00ab tz:Chicago --- id:@b-0012 dis:Bravo Boiler Plant equip hot hvac plant siteRef:@b-0000 spaceRef:@b-00ab water --- id:@b-0013 dis:Bravo Boiler Plant Domestic Hot Water Leaving Temperature Setpoint cur custom:{sourcePointName:"HwSp" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} domestic equipRef:@b-0012 his hot kind:Number leaving point siteRef:@b-0000 sp spaceRef:@b-00ab temp tz:Chicago unit:°F water --- id:@b-0014 dis:Bravo Boiler Plant Heating Hot Water Differential Pressure Setpoint cur custom:{sourcePointName:"HWDifSP" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} delta equipRef:@b-0012 his hot kind:Number point pressure siteRef:@b-0000 sp spaceRef:@b-00ab tz:Chicago unit:psi water --- id:@b-0015 dis:Bravo Boiler Plant Heating Hot Water Return Temperature cur custom:{sourcePointName:"HWRTEMP" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0012 heating his kind:Number leaving point sensor siteRef:@b-0000 spaceRef:@b-00ab temp tz:Chicago unit:°F water --- id:@b-0016 dis:Bravo Boiler Plant Heating Hot Water Supply Temperature cur custom:{sourcePointName:"HWSTEMP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0012 his hot kind:Number leaving point sensor siteRef:@b-0000 spaceRef:@b-00ab temp tz:Chicago unit:°F water --- id:@b-0017 dis:Bravo CHW System custom:{equipType} siteRef:@b-0000 space --- id:@b-0018 dis:Bravo CHWP-1 chilled equip hvac pump siteRef:@b-0000 spaceRef:@b-0017 water --- id:@b-0019 dis:Bravo CHWP-1 Chilled Water Pump Enable chilled cur custom:{poinTags:"point and chilled and water and cmd and pump" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York backgroundPoint} enum:"Stop,Running" equipRef:@b-0018 his kind:Bool point pump sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago water --- id:@b-001a dis:Bravo CHWP-1 Chilled Water Pump VFD Speed chilled cur custom:{dataSyncDownSince:2020-07-14T01:00:03.512-04:00 New_York precision:2 dataSyncType:"error" backgroundPoint} equipRef:@b-0018 his kind:Number point pump sensor siteRef:@b-0000 spaceRef:@b-0017 speed tz:Chicago unit:"%" water --- id:@b-001b dis:Bravo CHWP-2 chilled equip hvac pump siteRef:@b-0000 spaceRef:@b-0017 water --- id:@b-001c dis:Bravo CHWP-2 Chilled Water Pump Enable chilled cur custom:{dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York backgroundPoint} enum:"Stop,Running" equipRef:@b-001b his kind:Bool point pump sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago water --- id:@b-001d dis:Bravo CHWP-2 Chilled Water Pump VFD Speed chilled cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York backgroundPoint} equipRef:@b-001b his kind:Number point pump sensor siteRef:@b-0000 spaceRef:@b-0017 speed tz:Chicago unit:"%" water --- id:@b-001e dis:Bravo Chilled Water Plant chilled equip hvac plant siteRef:@b-0000 spaceRef:@b-0017 water --- id:@b-001f dis:Bravo Chilled Water Plant AHU Cooling Enable cmd cooling cur custom:{sourcePointName:"AHUClgEnable" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York backgroundPoint} enable equipRef:@b-001e his kind:Bool point siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago --- id:@b-0020 dis:Bravo Chilled Water Plant AHU Heating Enable cmd cur custom:{sourcePointName:"AHUHtgEnable" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York backgroundPoint} enable equipRef:@b-001e heating his kind:Bool point siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago --- id:@b-0021 dis:"Bravo Chilled Water Plant CV-1 Valve Signal (HHW)" cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York backgroundPoint} equipRef:@b-001e his hot kind:Number maxVal:100 minVal:0 point sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:"%" valve water --- id:@b-0022 dis:"Bravo Chilled Water Plant CV-2 Valve Signal (Bypass Valve)" bypass chilled cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York signal backgroundPoint} equipRef:@b-001e his kind:Number maxVal:100 minVal:0 point sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:"%" valve water --- id:@b-0023 dis:Bravo Chilled Water Plant CV-3 Valve Signal chilled cur custom:{precision:0 dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York signal backgroundPoint} equipRef:@b-001e his kind:Number maxVal:100 minVal:0 point sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:"%" valve water --- id:@b-0024 dis:Bravo Chilled Water Plant CV-4 Valve Signal chilled cur custom:{precision:0 dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York signal backgroundPoint} equipRef:@b-001e his kind:Number maxVal:100 minVal:0 point sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:"%" valve water --- id:@b-0025 dis:Bravo Chilled Water Plant Chilled Water Differential Pressure chilled cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York pointType:"" backgroundPoint} delta equipRef:@b-001e his kind:Number point pressure sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:psi water --- id:@b-0026 dis:Bravo Chilled Water Plant Chilled Water Differential Pressure Setpoint chilled cur custom:{predictionConf:0.3397244142906628 sourcePointName:"ChwDifSP" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} delta equipRef:@b-001e his kind:Number point pressure primaryLoop sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:psi water --- id:@b-0027 dis:Bravo Chilled Water Plant Chilled Water Entering Temperature chilled cur custom:{predictionConf:0.787900067809321 sourcePointName:"CHWRTEMP" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} entering equipRef:@b-001e his kind:Number point primaryLoop sensor siteRef:@b-0000 spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-0028 dis:Bravo Chilled Water Plant Chilled Water Leaving Temperature chilled cur custom:{predictionConf:0.787900067809321 sourcePointName:"ChwsTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-001e his kind:Number leaving point primaryLoop sensor siteRef:@b-0000 spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-0029 dis:"Bravo Chilled Water Plant Chilled Water dT (Auto-computed)" custom:{cache dataSyncDownSince:2020-03-12T01:00:04.793-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-001e his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0017 tz:Chicago --- id:@b-002a dis:Bravo Chilled Water Plant Chiller Status chiller cur custom:{predictionConf:0.15013386549340826 sourcePointName:"RunSTATUS" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-001e his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago --- id:@b-002b dis:"Bravo Chilled Water Plant Efficiency (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-001e his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0017 tz:Chicago unit:"kW/ton" --- id:@b-002c dis:Bravo Chiller 1 airCooling chilledWaterRef:@b-001e chiller custom:{designElecPower:180kW designEfficiency:10.6EER designSource:"Drawings" designChilledWaterPower:160tonref designChilledWaterLeavingTemp:44°F designMake:"Mcquay" designChilledWaterEnteringTemp:58°F designChilledWaterDeltaPressure:18.61psi designModel:"AGS-160C" designChilledWaterFlow:275gal/min} equip hvac siteRef:@b-0000 spaceRef:@b-0017 --- id:@b-002d dis:Bravo Chiller 1 Chilled Water Entering Temperature chilled cur custom:{predictionConf:0.38428817764444545 sourcePointName:"CH1_EntChwTemp" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} entering equipRef:@b-002c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-002e dis:Bravo Chiller 1 Chilled Water Leaving Temperature chilled cur custom:{predictionConf:0.34916172794461753 sourcePointName:"CH1_LeavChwTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-002c his kind:Number leaving point sensor siteRef:@b-0000 spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-002f dis:"Bravo Chiller 1 Chilled Water dT (Auto-computed)" custom:{cache dataSyncDownSince:2020-03-12T01:00:04.793-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-002c his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0017 tz:Chicago --- id:@b-0030 dis:Bravo Chiller 1 Chiller 1 Setpoint chilled chiller cur custom:{predictionConf:0.42372423437084655 sourcePointName:"CH1_CHW_SP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York pointType:"" inScope backgroundPoint} equipRef:@b-002c his kind:Number leaving point siteRef:@b-0000 sp spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-0031 dis:"Bravo Chiller 1 Chiller Act. Capacity" chiller cur custom:{act precision:2 dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York backgroundPoint capacity} equipRef:@b-002c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:"%" --- id:@b-0032 dis:Bravo Chiller 1 Chiller Enable chiller cmd cur custom:{predictionConf:0.2769995097894551 sourcePointName:"CH1_Clr1Cmd" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-002c his kind:Bool point run siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago --- id:@b-0033 dis:Bravo Chiller 1 Chiller Status chiller cur custom:{predictionConf:0.33026119584467384 sourcePointName:"CH1_ChlrSts" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-002c his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago --- id:@b-0034 dis:Bravo Chiller 2 airCooling chilledWaterRef:@b-001e chiller custom:{designElecPower:180kW designEfficiency:10.6EER designSource:"Drawings" designChilledWaterPower:160tonref designChilledWaterLeavingTemp:44°F designMake:"Mcquay" designChilledWaterEnteringTemp:58°F designChilledWaterDeltaPressure:18.61psi designModel:"AGS-160C" designChilledWaterFlow:275gal/min} equip hvac siteRef:@b-0000 spaceRef:@b-0017 --- id:@b-0035 dis:Bravo Chiller 2 Chilled Water Entering Temperature chilled cur custom:{predictionConf:0.38428817764444545 sourcePointName:"CH2_EntChwTemp" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} entering equipRef:@b-0034 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-0036 dis:Bravo Chiller 2 Chilled Water Leaving Temperature chilled cur custom:{predictionConf:0.34916172794461753 sourcePointName:"CH2_LeavChwTemp" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0034 his kind:Number leaving point sensor siteRef:@b-0000 spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-0037 dis:"Bravo Chiller 2 Chilled Water dT (Auto-computed)" custom:{cache dataSyncDownSince:2020-03-12T01:00:04.793-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-0034 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0017 tz:Chicago --- id:@b-0038 dis:Bravo Chiller 2 Chiller 2 Setpoint chilled chiller cur custom:{predictionConf:0.42372423437084655 sourcePointName:"CH2_CHW_SP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York pointType:"" inScope backgroundPoint} equipRef:@b-0034 his kind:Number leaving point siteRef:@b-0000 sp spaceRef:@b-0017 temp tz:Chicago unit:°F water --- id:@b-0039 dis:"Bravo Chiller 2 Chiller Act. Capacity" chiller cur custom:{act precision:2 dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York backgroundPoint capacity} equipRef:@b-0034 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago unit:"%" --- id:@b-003a dis:Bravo Chiller 2 Chiller Enable chiller cmd cur custom:{predictionConf:0.2769995097894551 sourcePointName:"CH2_Clr1Cmd" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-0034 his kind:Bool point run siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago --- id:@b-003b dis:Bravo Chiller 2 Chiller Status chiller cur custom:{predictionConf:0.33026119584467384 sourcePointName:"CH2_ChlrSts" dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York inScope backgroundPoint} equipRef:@b-0034 his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-0017 tz:Chicago --- id:@b-003c dis:Bravo EF-1 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-003d dis:Bravo EF-1 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} enable equipRef:@b-003c exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-003e dis:Bravo EF-1 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" pointType:"" inScope backgroundPoint} equipRef:@b-003c exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-003f dis:Bravo EF-10 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0040 dis:Bravo EF-10 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} enable equipRef:@b-003f exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0041 dis:Bravo EF-10 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-06-23T01:00:04.326-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-003f exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0042 dis:Bravo EF-11 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0043 dis:Bravo EF-11 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0042 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0044 dis:Bravo EF-11 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.945-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0042 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0045 dis:Bravo EF-12 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0046 dis:Bravo EF-12 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0045 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0047 dis:Bravo EF-12 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0045 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0048 dis:Bravo EF-13 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0049 dis:Bravo EF-13 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0048 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-004a dis:Bravo EF-13 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0048 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-004b dis:Bravo EF-14 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-004c dis:Bravo EF-14 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} enable equipRef:@b-004b exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-004d dis:Bravo EF-14 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-004b exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-004e dis:Bravo EF-15 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-004f dis:Bravo EF-15 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} enable equipRef:@b-004e exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0050 dis:Bravo EF-15 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-004e exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0051 dis:Bravo EF-16 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0052 dis:Bravo EF-16 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0051 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0053 dis:Bravo EF-16 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0051 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0054 dis:Bravo EF-17 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0055 dis:Bravo EF-17 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0054 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0056 dis:Bravo EF-17 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.945-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0054 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0057 dis:Bravo EF-18 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0058 dis:Bravo EF-18 Exhaust Fan Enable cur custom:{dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York backgroundPoint} enable enum:"STOP,On" equipRef:@b-0057 exhaust fan his kind:Bool point sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0059 dis:Bravo EF-18 Exhaust Fan Status cur custom:{dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York backgroundPoint} enum:"stateNul,Off,RUNNING" equipRef:@b-0057 exhaust fan his kind:Str point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-005a dis:Bravo EF-19 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-005b dis:Bravo EF-19 Exhaust Fan Enable cur custom:{dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York backgroundPoint} enable enum:"STOP,On" equipRef:@b-005a exhaust fan his kind:Bool point sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-005c dis:Bravo EF-19 Exhaust Fan Status cur custom:{dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York backgroundPoint} enum:"stateNul,Off,RUNNING" equipRef:@b-005a exhaust fan his kind:Str point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-005d dis:Bravo EF-2 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-005e dis:Bravo EF-2 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} enable equipRef:@b-005d exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-005f dis:Bravo EF-2 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.945-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-005d exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0060 dis:Bravo EF-20 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0061 dis:Bravo EF-20 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0060 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0062 dis:Bravo EF-20 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.945-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0060 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0063 dis:Bravo EF-21 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0064 dis:Bravo EF-21 Exhaust Fan Enable cur custom:{dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York backgroundPoint} enable enum:"STOP,On" equipRef:@b-0063 exhaust fan his kind:Bool point sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0065 dis:Bravo EF-21 Exhaust Fan Status cur custom:{dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York backgroundPoint} enum:"stateNul,Off,RUNNING" equipRef:@b-0063 exhaust fan his kind:Str point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0066 dis:Bravo EF-22 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0067 dis:Bravo EF-22 Exhaust Fan Enable cur custom:{dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York backgroundPoint} enable enum:"STOP,On" equipRef:@b-0066 exhaust fan his kind:Bool point sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0068 dis:Bravo EF-22 Exhaust Fan Status cur custom:{dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York backgroundPoint} enum:"stateNul,Off,RUNNING" equipRef:@b-0066 exhaust fan his kind:Str point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0069 dis:Bravo EF-23 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-006a dis:Bravo EF-23 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EF23SS" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0069 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-006b dis:Bravo EF-23 Exhaust Fan Status cur custom:{sourcePointName:"EF23Status" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0069 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-006c dis:Bravo EF-24 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-006d dis:Bravo EF-24 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} enable equipRef:@b-006c exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-006e dis:Bravo EF-24 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-006c exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-006f dis:Bravo EF-25 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0070 dis:Bravo EF-25 Exhaust Fan Enable cur custom:{dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York backgroundPoint} enable enum:"STOP,On" equipRef:@b-006f exhaust fan his kind:Bool point sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0071 dis:Bravo EF-25 Exhaust Fan Status cur custom:{dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York backgroundPoint} enum:"stateNul,Off,RUNNING" equipRef:@b-006f exhaust fan his kind:Str point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0072 dis:Bravo EF-26 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0073 dis:Bravo EF-26 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0072 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0074 dis:Bravo EF-26 Exhaust Fan Status cur custom:{sourcePointName:"EFStatus" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0072 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0075 dis:Bravo EF-27 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0076 dis:Bravo EF-27 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0075 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0077 dis:Bravo EF-27 Exhaust Fan Status cur custom:{sourcePointName:"EFStatus" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-0075 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0078 dis:Bravo EF-28 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0079 dis:Bravo EF-28 Exhaust Fan Status cur custom:{sourcePointName:"EF28Status" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0078 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-007a dis:Bravo EF-3 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-007b dis:Bravo EF-3 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} enable equipRef:@b-007a exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-007c dis:Bravo EF-3 Exhaust Fan Status cur custom:{sourcePointName:"EFStatus" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-007a exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-007d dis:Bravo EF-4 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-007e dis:Bravo EF-4 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} enable equipRef:@b-007d exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-007f dis:Bravo EF-4 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.945-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-007d exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0080 dis:Bravo EF-5 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0081 dis:Bravo EF-5 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0080 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0082 dis:Bravo EF-5 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0080 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0083 dis:Bravo EF-6 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0084 dis:Bravo EF-6 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0083 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0085 dis:Bravo EF-6 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-05-28T01:00:09.102-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0083 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0086 dis:Bravo EF-7 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-0087 dis:Bravo EF-7 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0086 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0088 dis:Bravo EF-7 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.929-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0086 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-0089 dis:Bravo EF-8 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-008a dis:Bravo EF-8 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0089 exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-008b dis:Bravo EF-8 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-03-11T13:56:25.945-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" inScope backgroundPoint} equipRef:@b-0089 exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-008c dis:Bravo EF-9 equip fan hvac siteRef:@b-0000 spaceRef:@b-00a4 --- id:@b-008d dis:Bravo EF-9 Exhaust Fan Enable cmd cur custom:{sourcePointName:"EFSS" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} enable equipRef:@b-008c exhaust fan his kind:Bool point siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-008e dis:Bravo EF-9 Exhaust Fan Status cur custom:{dataSyncDownSince:2020-07-02T01:00:04.305-04:00 New_York sourcePointName:"EFStatus" dataSyncType:"error" pointType:"" inScope backgroundPoint} equipRef:@b-008c exhaust fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-00a4 tz:Chicago --- id:@b-008f dis:Bravo FCU-1 chilledWaterCooling chilledWaterRef:@b-001e directZone elecHeating equip fcu hvac singleDuct siteRef:@b-0000 spaceRef:@b-00a3 thermostat zone --- id:@b-0090 dis:Bravo FCU-1 Cooling Valve Output chilled cool cur custom:{sourcePointName:"ChwVlv" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-008f his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve water --- id:@b-0091 dis:Bravo FCU-1 Heating Valve Output cur custom:{precision:0 dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York backgroundPoint} equipRef:@b-008f heat his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve --- id:@b-0092 dis:Bravo FCU-1 Zone Temperature air cur custom:{sourcePointName:"SpcTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-008f his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-0093 dis:Bravo FCU-1 Zone Temperature Setpoint air cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York backgroundPoint} equipRef:@b-008f his kind:Number maxVal:327 minVal:-273 point siteRef:@b-0000 sp spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-0094 dis:Bravo FCU-2 chilledWaterCooling chilledWaterRef:@b-001e directZone elecHeating equip fcu hvac singleDuct siteRef:@b-0000 spaceRef:@b-00a3 thermostat zone --- id:@b-0095 dis:Bravo FCU-2 Cooling Valve Output chilled cool cur custom:{sourcePointName:"ChwVlv" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0094 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve water --- id:@b-0096 dis:Bravo FCU-2 Heating Valve Output cur custom:{precision:0 dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York backgroundPoint} equipRef:@b-0094 heat his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve --- id:@b-0097 dis:Bravo FCU-2 Zone Temperature air cur custom:{sourcePointName:"SpcTemp" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0094 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-0098 dis:Bravo FCU-2 Zone Temperature Setpoint air cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York backgroundPoint} equipRef:@b-0094 his kind:Number maxVal:327 minVal:-273 point siteRef:@b-0000 sp spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-0099 dis:Bravo FCU-3 chilledWaterCooling chilledWaterRef:@b-001e directZone elecHeating equip fcu hvac singleDuct siteRef:@b-0000 spaceRef:@b-00a3 thermostat zone --- id:@b-009a dis:Bravo FCU-3 Cooling Valve Output chilled cool cur custom:{sourcePointName:"ChwVlv" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0099 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve water --- id:@b-009b dis:Bravo FCU-3 Heating Valve Output cur custom:{precision:0 dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York backgroundPoint} equipRef:@b-0099 heat his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve --- id:@b-009c dis:Bravo FCU-3 Zone Temperature air cur custom:{sourcePointName:"SpcTemp" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0099 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-009d dis:Bravo FCU-3 Zone Temperature Setpoint air cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York backgroundPoint} equipRef:@b-0099 his kind:Number maxVal:327 minVal:-273 point siteRef:@b-0000 sp spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-009e dis:Bravo FCU-4 chilledWaterCooling chilledWaterRef:@b-001e directZone elecHeating equip fcu hvac singleDuct siteRef:@b-0000 spaceRef:@b-00a3 thermostat zone --- id:@b-009f dis:Bravo FCU-4 Cooling Valve Output chilled cool cur custom:{sourcePointName:"ChwVlv" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-009e his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve water --- id:@b-00a0 dis:Bravo FCU-4 Heating Valve Output cur custom:{precision:0 dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York backgroundPoint} equipRef:@b-009e heat his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 tz:Chicago unit:"%" valve --- id:@b-00a1 dis:Bravo FCU-4 Zone Temperature air cur custom:{sourcePointName:"SpcTemp" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-009e his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-00a2 dis:Bravo FCU-4 Zone Temperature Setpoint air cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York backgroundPoint} equipRef:@b-009e his kind:Number maxVal:327 minVal:-273 point siteRef:@b-0000 sp spaceRef:@b-00a3 temp tz:Chicago unit:°F zone --- id:@b-00a3 dis:Bravo FCUs custom:{equipType} siteRef:@b-0000 space --- id:@b-00a4 dis:Bravo Fans custom:{equipType} siteRef:@b-0000 space --- id:@b-00a5 dis:Bravo HHW Pump 1 equip hot hvac pump siteRef:@b-0000 spaceRef:@b-00ab water --- id:@b-00a6 dis:Bravo HHW Pump 1 HHW Pump Status cur custom:{dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York backgroundPoint status} enum:"false,true" equipRef:@b-00a5 his hot kind:Bool point pump sensor siteRef:@b-0000 spaceRef:@b-00ab tz:Chicago water --- id:@b-00a7 dis:Bravo HHW Pump 1 HHW Pump VFD Speed cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York backgroundPoint} equipRef:@b-00a5 his hot kind:Number point pump sensor siteRef:@b-0000 spaceRef:@b-00ab speed tz:Chicago water --- id:@b-00a8 dis:Bravo HHW Pump 2 equip hot hvac pump siteRef:@b-0000 spaceRef:@b-00ab water --- id:@b-00a9 dis:Bravo HHW Pump 2 HHW Pump Status cur custom:{dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York backgroundPoint status} enum:"false,true" equipRef:@b-00a8 his hot kind:Bool point pump sensor siteRef:@b-0000 spaceRef:@b-00ab tz:Chicago water --- id:@b-00aa dis:Bravo HHW Pump 2 HHW Pump VFD Speed cur custom:{precision:2 dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York backgroundPoint} equipRef:@b-00a8 his hot kind:Number point pump sensor siteRef:@b-0000 spaceRef:@b-00ab speed tz:Chicago water --- id:@b-00ab dis:Bravo HW System custom:{equipType} siteRef:@b-0000 space --- id:@b-00ac dis:Bravo RTU-1 ahu chilledWaterCooling custom:{designDischargeAirFlow:15300cfm steamHumidifier designHotWaterLeavingTemp:65°F designHotWaterPower:145MMBTU/h designOutsideAirFlowMin:3500cfm designDischargeFanAirDeltaPressure:7.04inH₂O designSource:"Drawings" designChilledWaterLeavingTemp:59°F designChilledWaterPower:722.3MMBTU/h designHotWaterFlow:24.1gal/min designChilledWaterFlow:96.4gal/min designReturnAirFlow:15300cfm designHotWaterEnteringTemp:75°F designOutsideAirFlow:15300cfm designReturnFanPower:15hp designChilledWaterEnteringTemp:44°F designDischargeFanPower:40hp designReturnFanAirDeltaPressure:1.66inH₂O} equip hotWaterHeating hvac rtu singleDuct siteRef:@b-0000 spaceRef:@b-0135 vavZone --- id:@b-00ad dis:Bravo RTU-1 AHU Operation Mode computed custom:{mode dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ac his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00ae dis:Bravo RTU-1 Cooling Valve Output chilled cmd cool cur custom:{sourcePointName:"CWV" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" valve water --- id:@b-00af dis:Bravo RTU-1 Exhaust Air Damper Output air cur custom:{sourcePointName:"EAD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00ac exhaust his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00b0 dis:"Bravo RTU-1 Fan Power (Auto-computed)" custom:{cache dataSyncDownSince:2020-04-09T01:00:02.664-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-00ac his kind:Number point siteRef:@b-0000 sp tz:Chicago --- id:@b-00b1 dis:"Bravo RTU-1 Heating/Cooling Load (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ac his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"BTU/h" --- id:@b-00b2 dis:Bravo RTU-1 Humidifier Enable cmd cur custom:{sourcePointName:"HUM_ENABLE" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} enable equipRef:@b-00ac his humidifier kind:Bool point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00b3 dis:Bravo RTU-1 Humidifier Output cmd cur custom:{sourcePointName:"HUM VLV" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac his humidifier kind:Number point siteRef:@b-0000 spaceRef:@b-0135 steam tz:Chicago unit:"%" valve --- id:@b-00b4 dis:Bravo RTU-1 Max Damper Position cmd computed custom:{max dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} damper equipRef:@b-00ac his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00b5 dis:Bravo RTU-1 Min Outdoor Air Flow Setpoint air cur custom:{min sourcePointName:"MinOA_SP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York pointType:"" inScope backgroundPoint} equipRef:@b-00ac flow his kind:Number outside point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00b6 dis:"Bravo RTU-1 Min Outdoor Air Flow/10" air cur custom:{min sourcePointName:"MIN OA CFM / 10" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac flow his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00b7 dis:Bravo RTU-1 Minimum Outside Air Damper Output air cur custom:{sourcePointName:"Min OAD" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope outsideMin backgroundPoint} damper equipRef:@b-00ac his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00b8 dis:Bravo RTU-1 Mixed Air Temperature air cur custom:{sourcePointName:"MAT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac his kind:Number mixed point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00b9 dis:Bravo RTU-1 Mixed Air Temperature Setpoint air cur custom:{sourcePointName:"MAT STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac his kind:Number mixed point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00ba dis:Bravo RTU-1 Outside Air Damper Output air cmd cur custom:{sourcePointName:"OAD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00ac his kind:Number outside point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00bb dis:Bravo RTU-1 Outside Air Flow air cur custom:{sourcePointName:"OA CFM" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac flow his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00bc dis:"Bravo RTU-1 Outside Air Percentage (Auto-computed)" custom:{cache dataSyncDownSince:2020-04-09T01:00:02.656-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-00ac his kind:Number point siteRef:@b-0000 sp tz:Chicago --- id:@b-00bd dis:Bravo RTU-1 Percent Outside Air air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ac his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:"%" --- id:@b-00be dis:Bravo RTU-1 Return Air Damper Output air cur custom:{sourcePointName:"RET/REL DAMPER" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00ac his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00bf dis:Bravo RTU-1 Return Air Flow air cur custom:{sourcePointName:"RA CFM" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac flow his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00c0 dis:Bravo RTU-1 Return Air Humidity air cur custom:{sourcePointName:"RAH" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac his humidity kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00c1 dis:Bravo RTU-1 Return Air Temperature air cur custom:{sourcePointName:"RAT" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00c2 dis:Bravo RTU-1 Return Fan Status air cur custom:{sourcePointName:"RF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac fan his kind:Bool point return run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00c3 dis:Bravo RTU-1 Return Fan VFD Speed air cur custom:{sourcePointName:"ACT_OUTPUT_SPEED" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} equipRef:@b-00ac fan his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 speed tz:Chicago unit:"%" --- id:@b-00c4 dis:Bravo RTU-1 Supply Air Flow air cur custom:{sourcePointName:"SA CFM" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00c5 dis:Bravo RTU-1 Supply Air Humidity air cur custom:{sourcePointName:"DAH" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00c6 dis:Bravo RTU-1 Supply Air Humidity Setpoint air cur custom:{sourcePointName:"Humidity SP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac his humidity kind:Number point pointFunction:^sp siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00c7 dis:Bravo RTU-1 Supply Air Pressure Setpoint air cur custom:{static sourcePointName:"Static Stpt" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac his kind:Number point pressure siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-00c8 dis:Bravo RTU-1 Supply Air Static Pressure air cur custom:{sourcePointName:"DISCH STATIC" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac his kind:Number point pressure sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-00c9 dis:Bravo RTU-1 Supply Air Temperature air cur custom:{sourcePointName:"DAT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00ca dis:Bravo RTU-1 Supply Air Temperature Setpoint air cur custom:{sourcePointName:"DAT STPT" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00cb dis:Bravo RTU-1 Supply Fan Status air cur custom:{sourcePointName:"SF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ac fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00cc dis:"Bravo RTU-1 TU Air Flow (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ac his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00cd dis:Bravo RTU-1 VAV Total Flow air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ac flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00ce dis:Bravo RTU-2 ahu chilledWaterCooling custom:{designDischargeAirFlow:30000cfm steamHumidifier designHotWaterLeavingTemp:65°F designHotWaterPower:288MMBTU/h designOutsideAirFlowMin:6750cfm designDischargeFanAirDeltaPressure:6.4inH₂O designSource:"Drawings" designChilledWaterLeavingTemp:59.2°F designChilledWaterPower:1225.8MMBTU/h designHotWaterFlow:48gal/min designChilledWaterFlow:160.9gal/min designReturnAirFlow:30000cfm designHotWaterEnteringTemp:75°F designOutsideAirFlow:30000cfm designReturnFanPower:25hp designChilledWaterEnteringTemp:44°F designDischargeFanPower:50hp designReturnFanAirDeltaPressure:1.62inH₂O} equip hotWaterHeating hvac rtu singleDuct siteRef:@b-0000 spaceRef:@b-0135 vavZone --- id:@b-00cf dis:Bravo RTU-2 AHU Operation Mode computed custom:{mode dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ce his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00d0 dis:Bravo RTU-2 Calculated Outdoor Air Flow Setpoint air cur custom:{predictionConf:0.3970116854281743 sourcePointName:"MinOA_SP" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce flow his kind:Number outside point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00d1 dis:Bravo RTU-2 Cooling Valve Output chilled cmd cool cur custom:{predictionConf:0.5846394026860828 sourcePointName:"CWV" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" valve water --- id:@b-00d2 dis:Bravo RTU-2 Exhaust Air Damper Output air cur custom:{predictionConf:0.6232903565384572 sourcePointName:"EAD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00ce exhaust his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00d3 dis:"Bravo RTU-2 Fan Power (Auto-computed)" custom:{cache dataSyncDownSince:2020-04-09T01:00:02.664-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-00ce his kind:Number point siteRef:@b-0000 sp tz:Chicago --- id:@b-00d4 dis:"Bravo RTU-2 Heating/Cooling Load (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ce his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"BTU/h" --- id:@b-00d5 dis:Bravo RTU-2 Humidifier Enable cmd cur custom:{predictionConf:0.2169429859073283 sourcePointName:"HUM_ENABLE" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} enable equipRef:@b-00ce his humidifier kind:Bool point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00d6 dis:Bravo RTU-2 Humidifier Output cmd cur custom:{predictionConf:0.7439557600414519 sourcePointName:"HUM VLV" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce his humidifier kind:Number point siteRef:@b-0000 spaceRef:@b-0135 steam tz:Chicago unit:"%" valve --- id:@b-00d7 dis:Bravo RTU-2 Max Damper Position cmd computed custom:{max dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} damper equipRef:@b-00ce his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00d8 dis:Bravo RTU-2 Min OA Flow Setpoint air cur custom:{predictionConf:0.2305698711556413 sourcePointName:"MINOASTPT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope outsideMin backgroundPoint} equipRef:@b-00ce flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00d9 dis:Bravo RTU-2 Min Outdoor Air Flow air cur custom:{predictionConf:0.5591032698291575 min sourcePointName:"MIN OA CFM / 10" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce flow his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00da dis:Bravo RTU-2 Minimum Outside Air Damper Output air cur custom:{predictionConf:0.7226466689139898 sourcePointName:"Min OAD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope outsideMin backgroundPoint} damper equipRef:@b-00ce his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00db dis:Bravo RTU-2 Mixed Air Temperature air cur custom:{predictionConf:0.5092275130999935 sourcePointName:"MAT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce his kind:Number mixed point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00dc dis:Bravo RTU-2 Mixed Air Temperature Setpoint air cur custom:{predictionConf:0.41409123546331406 sourcePointName:"MAT STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce his kind:Number mixed point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00dd dis:Bravo RTU-2 Outside Air Damper Output air cmd cur custom:{predictionConf:0.7395401248861597 sourcePointName:"OAD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00ce his kind:Number outside point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00de dis:Bravo RTU-2 Outside Air Flow air cur custom:{predictionConf:0.7870789837941534 sourcePointName:"OA CFM" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce flow his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00df dis:"Bravo RTU-2 Outside Air Percentage (Auto-computed)" custom:{cache dataSyncDownSince:2020-03-12T01:00:04.793-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-00ce his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago --- id:@b-00e0 dis:Bravo RTU-2 Percent Outside Air air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ce his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:"%" --- id:@b-00e1 dis:Bravo RTU-2 Return Air Damper Output air cur custom:{predictionConf:0.3561100767369028 sourcePointName:"RET/REL DAMPER" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00ce his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00e2 dis:Bravo RTU-2 Return Air Flow air cur custom:{predictionConf:0.8263008623409421 sourcePointName:"RA CFM" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce flow his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00e3 dis:Bravo RTU-2 Return Air Humidity air cur custom:{predictionConf:0.7016271134196499 sourcePointName:"RAH" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce his humidity kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00e4 dis:Bravo RTU-2 Return Air Temperature air cur custom:{predictionConf:0.5745623242771728 sourcePointName:"RAT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00e5 dis:Bravo RTU-2 Return Fan Status air cur custom:{predictionConf:0.5721715629985896 sourcePointName:"RF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce fan his kind:Bool point return run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00e6 dis:Bravo RTU-2 Return Fan VFD Speed air cur custom:{predictionConf:0.13813130060214382 sourcePointName:"ACT_OUTPUT_SPEED" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce fan his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 speed tz:Chicago unit:"%" --- id:@b-00e7 dis:Bravo RTU-2 Supply Air Flow air cur custom:{predictionConf:0.7841375570046363 sourcePointName:"SA CFM" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00e8 dis:Bravo RTU-2 Supply Air Humidity air cur custom:{predictionConf:0.7933659564917551 sourcePointName:"DAH" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00e9 dis:Bravo RTU-2 Supply Air Humidity Setpoint air cur custom:{predictionConf:0.7045004074770955 sourcePointName:"Humidity SP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce his humidity kind:Number point pointFunction:^sp siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00ea dis:Bravo RTU-2 Supply Air Static Pressure air cur custom:{predictionConf:0.3539915786588711 sourcePointName:"DISCH STATIC" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce his kind:Number point pressure sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-00eb dis:Bravo RTU-2 Supply Air Static Pressure Setpoint air cur custom:{predictionConf:0.48636472322277824 sourcePointName:"Static Stpt" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce his kind:Number point pressure siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-00ec dis:Bravo RTU-2 Supply Air Temperature air cur custom:{predictionConf:0.5598774100147106 sourcePointName:"DAT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00ed dis:Bravo RTU-2 Supply Air Temperature Setpoint air cur custom:{predictionConf:0.6936845307741977 sourcePointName:"DAT STPT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00ee dis:Bravo RTU-2 Supply Fan Status air cur custom:{predictionConf:0.6818756457191736 sourcePointName:"SF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00ce fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00ef dis:Bravo RTU-2 Supply Fan VFD Speed air cur custom:{predictionConf:0.13813130060214382 sourcePointName:"ACT_OUTPUT_SPEED" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-00ce fan his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 speed tz:Chicago unit:"%" --- id:@b-00f0 dis:"Bravo RTU-2 TU Air Flow (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ce his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00f1 dis:Bravo RTU-2 VAV Total Flow air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00ce flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00f2 dis:Bravo RTU-3 ahu chilledWaterCooling custom:{designDischargeAirFlow:33600cfm steamHumidifier designHotWaterLeavingTemp:65°F designHotWaterPower:318MMBTU/h designOutsideAirFlowMin:7125cfm designDischargeFanAirDeltaPressure:6.7inH₂O designSource:"Drawings" designChilledWaterLeavingTemp:58.9°F designChilledWaterPower:1346.1MMBTU/h designHotWaterFlow:53gal/min designChilledWaterFlow:180.2gal/min designReturnAirFlow:33600cfm designHotWaterEnteringTemp:75°F designOutsideAirFlow:33600cfm designReturnFanPower:25hp designChilledWaterEnteringTemp:44°F designDischargeFanPower:60hp designReturnFanAirDeltaPressure:1.63inH₂O} equip hotWaterHeating hvac rtu singleDuct siteRef:@b-0000 spaceRef:@b-0135 vavZone --- id:@b-00f3 dis:Bravo RTU-3 AHU Operation Mode computed custom:{mode dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00f2 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00f4 dis:Bravo RTU-3 Cooling Valve Output chilled cmd cool cur custom:{predictionConf:0.5846394026860828 sourcePointName:"CWV" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" valve water --- id:@b-00f5 dis:Bravo RTU-3 Exhaust Air Damper Output air cur custom:{predictionConf:0.6232903565384572 sourcePointName:"EAD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00f2 exhaust his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00f6 dis:"Bravo RTU-3 Fan Power (Auto-computed)" custom:{cache dataSyncDownSince:2020-04-09T01:00:02.664-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-00f2 his kind:Number point siteRef:@b-0000 sp tz:Chicago --- id:@b-00f7 dis:"Bravo RTU-3 Heating/Cooling Load (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00f2 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"BTU/h" --- id:@b-00f8 dis:Bravo RTU-3 Humidifier Enable cmd cur custom:{predictionConf:0.2169429859073283 sourcePointName:"HUM_ENABLE" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} enable equipRef:@b-00f2 his humidifier kind:Bool point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-00f9 dis:Bravo RTU-3 Humidifier Output cmd cur custom:{predictionConf:0.7439557600414519 sourcePointName:"HUM VLV" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 his humidifier kind:Number point siteRef:@b-0000 spaceRef:@b-0135 steam tz:Chicago unit:"%" valve --- id:@b-00fa dis:Bravo RTU-3 Max Damper Position cmd computed custom:{max dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} damper equipRef:@b-00f2 his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00fb dis:Bravo RTU-3 Min OA Flow Setpoint air cur custom:{predictionConf:0.2305698711556413 sourcePointName:"MINOASTPT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope outsideMin backgroundPoint} equipRef:@b-00f2 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-00fc dis:Bravo RTU-3 Minimum Outside Air Damper Output air cur custom:{predictionConf:0.7226466689139898 sourcePointName:"Min OAD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope outsideMin backgroundPoint} damper equipRef:@b-00f2 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-00fd dis:Bravo RTU-3 Mixed Air Temperature air cur custom:{predictionConf:0.5092275130999935 sourcePointName:"MAT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 his kind:Number mixed point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00fe dis:Bravo RTU-3 Mixed Air Temperature Setpoint air cur custom:{predictionConf:0.41409123546331406 sourcePointName:"MAT STPT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 his kind:Number mixed point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-00ff dis:Bravo RTU-3 Outside Air Damper Output air cmd cur custom:{predictionConf:0.7395401248861597 sourcePointName:"OAD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00f2 his kind:Number outside point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-0100 dis:Bravo RTU-3 Outside Air Flow air cur custom:{predictionConf:0.7870789837941534 sourcePointName:"OA CFM" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 flow his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0101 dis:"Bravo RTU-3 Outside Air Percentage (Auto-computed)" custom:{cache dataSyncDownSince:2020-03-12T01:00:04.793-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-00f2 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago --- id:@b-0102 dis:Bravo RTU-3 Percent Outside Air air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00f2 his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:"%" --- id:@b-0103 dis:Bravo RTU-3 Return Air Damper Output air cmd cur custom:{predictionConf:0.3561100767369028 sourcePointName:"RET/REL DAMPER" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper equipRef:@b-00f2 his kind:Number point return siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-0104 dis:Bravo RTU-3 Return Air Flow air cur custom:{predictionConf:0.8263008623409421 sourcePointName:"RA CFM" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 flow his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0105 dis:Bravo RTU-3 Return Air Humidity air cur custom:{predictionConf:0.7016271134196499 sourcePointName:"RAH" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 his humidity kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-0106 dis:Bravo RTU-3 Return Air Temperature air cur custom:{predictionConf:0.5745623242771728 sourcePointName:"RAT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-0107 dis:Bravo RTU-3 Return Fan Status air cur custom:{predictionConf:0.5721715629985896 sourcePointName:"RF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 fan his kind:Bool point return run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-0108 dis:Bravo RTU-3 Return Fan VFD Speed air cur custom:{predictionConf:0.3324288739189246 sourcePointName:"RTDrvSpd" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} equipRef:@b-00f2 fan his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 speed tz:Chicago unit:"%" --- id:@b-0109 dis:Bravo RTU-3 Supply Air Flow air cur custom:{predictionConf:0.7841375570046363 sourcePointName:"SA CFM" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-010a dis:Bravo RTU-3 Supply Air Humidity air cur custom:{predictionConf:0.7933659564917551 sourcePointName:"DAH" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-010b dis:Bravo RTU-3 Supply Air Pressure Setpoint air cur custom:{predictionConf:0.48636472322277824 static sourcePointName:"Static Stpt" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 his kind:Number point pressure siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-010c dis:Bravo RTU-3 Supply Air Static Pressure air cur custom:{predictionConf:0.3539915786588711 sourcePointName:"DISCH STATIC" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 his kind:Number point pressure sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-010d dis:Bravo RTU-3 Supply Air Temperature air cur custom:{predictionConf:0.5598774100147106 sourcePointName:"DAT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-010e dis:Bravo RTU-3 Supply Air Temperature Setpoint air cur custom:{predictionConf:0.6936845307741977 sourcePointName:"DAT STPT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-010f dis:Bravo RTU-3 Supply Fan Status air cur custom:{predictionConf:0.6818756457191736 sourcePointName:"SF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-0110 dis:Bravo RTU-3 Supply Fan VFD Speed air cur custom:{predictionConf:0.32036669663302475 sourcePointName:"SPDrvSpd" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-00f2 fan his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 speed tz:Chicago unit:"%" --- id:@b-0111 dis:"Bravo RTU-3 TU Air Flow (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00f2 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0112 dis:Bravo RTU-3 VAV Total Flow air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-00f2 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0113 dis:Bravo RTU-4 ahu chilledWaterCooling custom:{designDischargeAirFlow:15700cfm steamHumidifier designHotWaterLeavingTemp:65°F designHotWaterPower:243MMBTU/h designOutsideAirFlowMin:7125cfm designDischargeFanAirDeltaPressure:4.76inH₂O designSource:"Drawings" designChilledWaterLeavingTemp:58.9°F designChilledWaterPower:1028.7MMBTU/h designHotWaterFlow:41gal/min designChilledWaterFlow:137.8gal/min designReturnAirFlow:25700cfm designHotWaterEnteringTemp:75°F designOutsideAirFlow:25700cfm designReturnFanPower:20hp designChilledWaterEnteringTemp:44°F designDischargeFanPower:40hp designReturnFanAirDeltaPressure:1.64inH₂O} equip hotWaterHeating hvac rtu singleDuct siteRef:@b-0000 spaceRef:@b-0135 vavZone --- id:@b-0114 dis:Bravo RTU-4 AHU Operation Mode computed custom:{mode dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-0113 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-0115 dis:Bravo RTU-4 Cooling Valve Output chilled cmd cool cur custom:{sourcePointName:"CWV" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" valve water --- id:@b-0116 dis:Bravo RTU-4 Exhaust Air Damper Output air cur custom:{sourcePointName:"EAD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper equipRef:@b-0113 exhaust his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-0117 dis:"Bravo RTU-4 Fan Power (Auto-computed)" custom:{cache dataSyncDownSince:2020-04-09T01:00:02.664-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-0113 his kind:Number point siteRef:@b-0000 sp tz:Chicago --- id:@b-0118 dis:"Bravo RTU-4 Heating/Cooling Load (Auto-computed)" custom:{cache dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-0113 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"BTU/h" --- id:@b-0119 dis:Bravo RTU-4 Humidifier Enable cmd cur custom:{sourcePointName:"HUM_ENABLE" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} enable equipRef:@b-0113 his humidifier kind:Bool point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-011a dis:Bravo RTU-4 Humidifier Output cmd cur custom:{sourcePointName:"HUM VLV" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 his humidifier kind:Number point siteRef:@b-0000 spaceRef:@b-0135 steam tz:Chicago unit:"%" valve --- id:@b-011b dis:Bravo RTU-4 Max Damper Position cmd computed custom:{max dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} damper equipRef:@b-0113 his kind:Number point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-011c dis:Bravo RTU-4 Min Outdoor Air Flow Setpoint air cur custom:{min sourcePointName:"MinOA_SP" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York pointType:"" inScope backgroundPoint} equipRef:@b-0113 flow his kind:Number outside point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-011d dis:"Bravo RTU-4 Min Outdoor Air Flow/10" air cur custom:{min sourcePointName:"MIN OA CFM / 10" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 flow his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-011e dis:Bravo RTU-4 Minimum Outside Air Damper Output air cur custom:{sourcePointName:"Min OAD" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope outsideMin backgroundPoint} damper equipRef:@b-0113 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-011f dis:Bravo RTU-4 Mixed Air Temperature air cur custom:{sourcePointName:"MAT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 his kind:Number mixed point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-0120 dis:Bravo RTU-4 Mixed Air Temperature Setpoint air cur custom:{sourcePointName:"MAT STPT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 his kind:Number mixed point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-0121 dis:Bravo RTU-4 Outside Air Damper Output air cmd cur custom:{sourcePointName:"OAD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper equipRef:@b-0113 his kind:Number outside point siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-0122 dis:Bravo RTU-4 Outside Air Flow air cur custom:{sourcePointName:"OA CFM" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 flow his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0123 dis:"Bravo RTU-4 Outside Air Percentage (Auto-computed)" custom:{cache dataSyncDownSince:2020-04-09T01:00:02.664-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-0113 his kind:Number point siteRef:@b-0000 sp tz:Chicago --- id:@b-0124 dis:Bravo RTU-4 Percent Outside Air air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-0113 his kind:Number outside point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:"%" --- id:@b-0125 dis:Bravo RTU-4 Return Air Damper Output air cur custom:{sourcePointName:"RET/REL DAMPER" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York pointType:"" inScope backgroundPoint} damper equipRef:@b-0113 his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-0126 dis:Bravo RTU-4 Return Air Flow air cur custom:{sourcePointName:"RA CFM" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 flow his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0127 dis:Bravo RTU-4 Return Air Humidity air cur custom:{sourcePointName:"RAH" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 his humidity kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-0128 dis:Bravo RTU-4 Return Air Temperature air cur custom:{sourcePointName:"RAT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-0129 dis:Bravo RTU-4 Return Fan Status air cur custom:{sourcePointName:"RF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 fan his kind:Bool point return run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-012a dis:Bravo RTU-4 Return Fan VFD Speed air cur custom:{sourcePointName:"ACT_OUTPUT_SPEED" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0113 fan his kind:Number point return sensor siteRef:@b-0000 spaceRef:@b-0135 speed tz:Chicago unit:"%" --- id:@b-012b dis:Bravo RTU-4 Supply Air Flow air cur custom:{sourcePointName:"SA CFM" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-012c dis:Bravo RTU-4 Supply Air Humidity air cur custom:{sourcePointName:"DAH" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-012d dis:Bravo RTU-4 Supply Air Humidity Setpoint air cur custom:{sourcePointName:"Humidity SP" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 his humidity kind:Number point pointFunction:^sp siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"%" --- id:@b-012e dis:Bravo RTU-4 Supply Air Pressure Setpoint air cur custom:{static sourcePointName:"Static Stpt" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 his kind:Number point pressure siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-012f dis:Bravo RTU-4 Supply Air Static Pressure air cur custom:{sourcePointName:"DISCH STATIC" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 his kind:Number point pressure sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:"inH₂O" --- id:@b-0130 dis:Bravo RTU-4 Supply Air Temperature air cur custom:{sourcePointName:"DAT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-0131 dis:Bravo RTU-4 Supply Air Temperature Setpoint air cur custom:{sourcePointName:"DAT STPT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 temp tz:Chicago unit:°F --- id:@b-0132 dis:Bravo RTU-4 Supply Fan Status air cur custom:{sourcePointName:"SF FAN STATUS" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0113 fan his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago --- id:@b-0133 dis:"Bravo RTU-4 TU Air Flow (Auto-computed)" custom:{cache dataSyncDownSince:2020-03-12T01:00:04.793-04:00 New_York dataSyncType:"error" backgroundPoint} equipRef:@b-0113 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0134 dis:Bravo RTU-4 VAV Total Flow air computed custom:{dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} equipRef:@b-0113 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-0135 tz:Chicago unit:cfm --- id:@b-0135 dis:Bravo RTUs custom:{equipType} siteRef:@b-0000 space --- id:@b-0136 dis:Bravo Steam Boiler A boiler custom:{designSource:"Drawings" designMake:"Lattner" designSteamPower:1350MMBTU/h designModel:"WLF-40"} equip hvac siteRef:@b-0000 spaceRef:@b-013c --- id:@b-0137 dis:Bravo Steam Boiler A Boiler Status boiler cur custom:{sourcePointName:"StmBlrAsts" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0136 his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-013c tz:Chicago --- id:@b-0138 dis:Bravo Steam Boiler B boiler custom:{designSource:"Drawings" designMake:"Lattner" designSteamPower:1350MMBTU/h designModel:"WLF-40"} equip hvac siteRef:@b-0000 spaceRef:@b-013c --- id:@b-0139 dis:Bravo Steam Boiler B Boiler Status boiler cur custom:{sourcePointName:"StmBlrBsts" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0138 his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-013c tz:Chicago --- id:@b-013a dis:Bravo Steam Boiler C boiler custom:{designSource:"Drawings" designMake:"Lattner" designSteamPower:1350MMBTU/h designModel:"WLF-40"} equip hvac siteRef:@b-0000 spaceRef:@b-013c --- id:@b-013b dis:Bravo Steam Boiler C Boiler Status boiler cur custom:{sourcePointName:"StmBlrCsts" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-013a his kind:Bool point run sensor siteRef:@b-0000 spaceRef:@b-013c tz:Chicago --- id:@b-013c dis:Bravo Steam System custom:{equipType} siteRef:@b-0000 space --- id:@b-013d dis:Bravo VAV 1-1 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:9.7MMBTU/h designHotWaterFlow:1gal/min designAirFlow:400cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-013e dis:Bravo VAV 1-1 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-013d his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-013f dis:Bravo VAV 1-1 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-013d flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0140 dis:Bravo VAV 1-1 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-013d flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0141 dis:Bravo VAV 1-1 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-013d heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0142 dis:Bravo VAV 1-1 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-013d his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0143 dis:Bravo VAV 1-1 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-013d his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0144 dis:Bravo VAV 1-10 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:6.5MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:375cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0145 dis:Bravo VAV 1-10 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0144 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0146 dis:Bravo VAV 1-10 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0144 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0147 dis:Bravo VAV 1-10 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0144 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0148 dis:Bravo VAV 1-10 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0144 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0149 dis:Bravo VAV 1-10 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0144 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-014a dis:Bravo VAV 1-10 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-0144 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-014b dis:Bravo VAV 1-10 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0144 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-014c dis:Bravo VAV 1-11 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:10.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-014d dis:Bravo VAV 1-11 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-014c his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-014e dis:Bravo VAV 1-11 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-014c flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-014f dis:Bravo VAV 1-11 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-014c flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0150 dis:Bravo VAV 1-11 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-014c heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0151 dis:Bravo VAV 1-11 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-014c his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0152 dis:Bravo VAV 1-11 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-014c his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0153 dis:Bravo VAV 1-11 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-014c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0154 dis:Bravo VAV 1-12 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:10.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0155 dis:Bravo VAV 1-12 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0154 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0156 dis:Bravo VAV 1-12 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0154 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0157 dis:Bravo VAV 1-12 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0154 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0158 dis:Bravo VAV 1-12 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0154 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0159 dis:Bravo VAV 1-12 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0154 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-015a dis:Bravo VAV 1-12 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0154 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-015b dis:Bravo VAV 1-12 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0154 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-015c dis:Bravo VAV 1-13 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:27MMBTU/h designHotWaterFlow:3gal/min designAirFlow:1000cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-015d dis:Bravo VAV 1-13 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-015c his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-015e dis:Bravo VAV 1-13 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-015c flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-015f dis:Bravo VAV 1-13 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-015c flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0160 dis:Bravo VAV 1-13 Heating Valve cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-015c heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0161 dis:Bravo VAV 1-13 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-015c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0162 dis:Bravo VAV 1-13 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-015c his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0163 dis:Bravo VAV 1-13 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-015c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0164 dis:Bravo VAV 1-14 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:4.5MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:250cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0165 dis:Bravo VAV 1-14 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0164 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0166 dis:Bravo VAV 1-14 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0164 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0167 dis:Bravo VAV 1-14 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0164 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0168 dis:Bravo VAV 1-14 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0164 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0169 dis:Bravo VAV 1-14 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0164 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-016a dis:Bravo VAV 1-14 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0164 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-016b dis:Bravo VAV 1-14 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0164 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-016c dis:Bravo VAV 1-15 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:6MMBTU/h designHotWaterFlow:1gal/min designAirFlow:400cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-016d dis:Bravo VAV 1-15 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-016c his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-016e dis:Bravo VAV 1-15 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-016c flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-016f dis:Bravo VAV 1-15 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-016c flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0170 dis:Bravo VAV 1-15 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-016c heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0171 dis:Bravo VAV 1-15 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York pointType:"" inScope backgroundPoint} discharge equipRef:@b-016c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0172 dis:Bravo VAV 1-15 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-016c his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0173 dis:Bravo VAV 1-15 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-016c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0174 dis:Bravo VAV 1-16 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:4.1MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0175 dis:Bravo VAV 1-16 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0174 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0176 dis:Bravo VAV 1-16 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0174 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0177 dis:Bravo VAV 1-16 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0174 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0178 dis:Bravo VAV 1-16 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0174 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0179 dis:Bravo VAV 1-16 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0174 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-017a dis:Bravo VAV 1-16 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0174 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-017b dis:Bravo VAV 1-16 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-0174 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-017c dis:Bravo VAV 1-17 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:6MMBTU/h designHotWaterFlow:1gal/min designAirFlow:400cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-017d dis:Bravo VAV 1-17 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-017c his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-017e dis:Bravo VAV 1-17 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-017c flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-017f dis:Bravo VAV 1-17 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-017c flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0180 dis:Bravo VAV 1-17 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-017c heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0181 dis:Bravo VAV 1-17 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-017c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0182 dis:Bravo VAV 1-17 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-017c his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0183 dis:Bravo VAV 1-17 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-017c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0184 dis:Bravo VAV 1-18 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:4.1MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0185 dis:Bravo VAV 1-18 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0184 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0186 dis:Bravo VAV 1-18 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0184 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0187 dis:Bravo VAV 1-18 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0184 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0188 dis:Bravo VAV 1-18 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0184 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0189 dis:Bravo VAV 1-18 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0184 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-018a dis:Bravo VAV 1-18 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0184 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-018b dis:Bravo VAV 1-18 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0184 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-018c dis:Bravo VAV 1-19 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:30.9MMBTU/h designHotWaterFlow:1.45gal/min designAirFlow:2400cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-018d dis:Bravo VAV 1-19 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-018c his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-018e dis:Bravo VAV 1-19 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-018c flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-018f dis:Bravo VAV 1-19 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-018c flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0190 dis:Bravo VAV 1-19 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-018c heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0191 dis:Bravo VAV 1-19 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-018c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0192 dis:Bravo VAV 1-19 Zone Air Humidity air cur custom:{predictionConf:0.6984488664169048 sourcePointName:"Humidity" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-018c his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" zone --- id:@b-0193 dis:Bravo VAV 1-19 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-018c his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0194 dis:Bravo VAV 1-19 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-018c his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0195 dis:Bravo VAV 1-2 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:17.5MMBTU/h designHotWaterFlow:2gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0196 dis:Bravo VAV 1-2 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0195 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0197 dis:Bravo VAV 1-2 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0195 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0198 dis:Bravo VAV 1-2 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0195 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0199 dis:Bravo VAV 1-2 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0195 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-019a dis:Bravo VAV 1-2 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0195 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-019b dis:Bravo VAV 1-2 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0195 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-019c dis:Bravo VAV 1-2 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0195 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-019d dis:Bravo VAV 1-20 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:10.8MMBTU/h designHotWaterFlow:0.28gal/min designAirFlow:800cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-019e dis:Bravo VAV 1-20 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-019d his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-019f dis:Bravo VAV 1-20 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-019d flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01a0 dis:Bravo VAV 1-20 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-019d flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01a1 dis:Bravo VAV 1-20 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-019d heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01a2 dis:Bravo VAV 1-20 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-019d his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01a3 dis:Bravo VAV 1-20 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-019d his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01a4 dis:Bravo VAV 1-20 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-019d his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01a5 dis:Bravo VAV 1-3 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:83.5MMBTU/h designHotWaterFlow:12gal/min designAirFlow:3000cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01a6 dis:Bravo VAV 1-3 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01a5 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01a7 dis:Bravo VAV 1-3 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01a5 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01a8 dis:Bravo VAV 1-3 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01a5 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01a9 dis:Bravo VAV 1-3 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-01a5 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01aa dis:Bravo VAV 1-3 Supply Air Humidity air cur custom:{sourcePointName:"DisChgrHumid" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York backgroundPoint} discharge equipRef:@b-01a5 his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01ab dis:Bravo VAV 1-3 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01a5 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01ac dis:Bravo VAV 1-3 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-01a5 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01ad dis:Bravo VAV 1-3 Zone Relative Humidity air cur custom:{predictionConf:0.7237593125289187 sourcePointName:"SpaceHum" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-01a5 his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" zone --- id:@b-01ae dis:Bravo VAV 1-3 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-01a5 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01af dis:Bravo VAV 1-4 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:3.8MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01b0 dis:Bravo VAV 1-4 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01af his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01b1 dis:Bravo VAV 1-4 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01af flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01b2 dis:Bravo VAV 1-4 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01af flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01b3 dis:Bravo VAV 1-4 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-01af heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01b4 dis:Bravo VAV 1-4 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01af his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01b5 dis:Bravo VAV 1-4 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-01af his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01b6 dis:Bravo VAV 1-4 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-01af his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01b7 dis:Bravo VAV 1-5 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:10.5MMBTU/h designHotWaterFlow:1.5gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01b8 dis:Bravo VAV 1-5 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01b7 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01b9 dis:Bravo VAV 1-5 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01b7 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01ba dis:Bravo VAV 1-5 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01b7 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01bb dis:Bravo VAV 1-5 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-01b7 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01bc dis:Bravo VAV 1-5 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01b7 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01bd dis:Bravo VAV 1-5 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-01b7 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01be dis:Bravo VAV 1-5 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-01b7 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01bf dis:Bravo VAV 1-6 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:83.5MMBTU/h designHotWaterFlow:12gal/min designAirFlow:3000cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01c0 dis:Bravo VAV 1-6 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01bf his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01c1 dis:Bravo VAV 1-6 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01bf flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01c2 dis:Bravo VAV 1-6 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01bf flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01c3 dis:Bravo VAV 1-6 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-01bf heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01c4 dis:Bravo VAV 1-6 Supply Air Humidity air cur custom:{sourcePointName:"DisChgrHumid" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York backgroundPoint} discharge equipRef:@b-01bf his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01c5 dis:Bravo VAV 1-6 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01bf his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01c6 dis:Bravo VAV 1-6 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-01bf his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01c7 dis:Bravo VAV 1-6 Zone Relative Humidity air cur custom:{sourcePointName:"SpaceHum" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-01bf his humidity kind:Number point pointFunction:^sensor sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" zone --- id:@b-01c8 dis:Bravo VAV 1-6 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-01bf his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01c9 dis:Bravo VAV 1-7 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:7.6MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01ca dis:Bravo VAV 1-7 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01c9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01cb dis:Bravo VAV 1-7 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01c9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01cc dis:Bravo VAV 1-7 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01c9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01cd dis:Bravo VAV 1-7 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-01c9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01ce dis:Bravo VAV 1-7 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01c9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01cf dis:Bravo VAV 1-7 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-01c9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01d0 dis:Bravo VAV 1-7 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-01c9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01d1 dis:Bravo VAV 1-8 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:4.8MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01d2 dis:Bravo VAV 1-8 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01d1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01d3 dis:Bravo VAV 1-8 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01d1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01d4 dis:Bravo VAV 1-8 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01d1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01d5 dis:Bravo VAV 1-8 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-01d1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01d6 dis:Bravo VAV 1-8 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01d1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01d7 dis:Bravo VAV 1-8 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-01d1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01d8 dis:Bravo VAV 1-8 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-01d1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01d9 dis:Bravo VAV 1-9 airRef:@b-00ac custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:15.3MMBTU/h designHotWaterFlow:1.75gal/min designAirFlow:875cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01da dis:Bravo VAV 1-9 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01d9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01db dis:Bravo VAV 1-9 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01d9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01dc dis:Bravo VAV 1-9 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01d9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01dd dis:Bravo VAV 1-9 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-01d9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01de dis:Bravo VAV 1-9 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01d9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01df dis:Bravo VAV 1-9 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-01d9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01e0 dis:Bravo VAV 1-9 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-01d9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01e1 dis:Bravo VAV 2-1 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:8.9MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01e2 dis:Bravo VAV 2-1 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01e1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01e3 dis:Bravo VAV 2-1 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01e1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01e4 dis:Bravo VAV 2-1 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01e1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01e5 dis:Bravo VAV 2-1 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-01e1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01e6 dis:Bravo VAV 2-1 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01e1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01e7 dis:Bravo VAV 2-1 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-01e1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01e8 dis:Bravo VAV 2-1 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-01e1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01e9 dis:Bravo VAV 2-10 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:4.3MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:175cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01ea dis:Bravo VAV 2-10 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01e9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01eb dis:Bravo VAV 2-10 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01e9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01ec dis:Bravo VAV 2-10 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01e9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01ed dis:Bravo VAV 2-10 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-01e9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01ee dis:Bravo VAV 2-10 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01e9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01ef dis:Bravo VAV 2-10 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-01e9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01f0 dis:Bravo VAV 2-10 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-01e9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01f1 dis:Bravo VAV 2-11 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01f2 dis:Bravo VAV 2-11 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01f1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01f3 dis:Bravo VAV 2-11 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01f1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01f4 dis:Bravo VAV 2-11 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01f1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01f5 dis:Bravo VAV 2-11 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-01f1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01f6 dis:Bravo VAV 2-11 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01f1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01f7 dis:Bravo VAV 2-11 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-01f1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01f8 dis:Bravo VAV 2-11 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-01f1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-01f9 dis:Bravo VAV 2-12 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:4.6MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:250cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-01fa dis:Bravo VAV 2-12 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-01f9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-01fb dis:Bravo VAV 2-12 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01f9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01fc dis:Bravo VAV 2-12 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-01f9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-01fd dis:Bravo VAV 2-12 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-01f9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-01fe dis:Bravo VAV 2-12 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-01f9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-01ff dis:Bravo VAV 2-12 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-01f9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0200 dis:Bravo VAV 2-12 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-01f9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0201 dis:Bravo VAV 2-13 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:8.9MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0202 dis:Bravo VAV 2-13 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0201 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0203 dis:Bravo VAV 2-13 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0201 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0204 dis:Bravo VAV 2-13 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0201 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0205 dis:Bravo VAV 2-13 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0201 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0206 dis:Bravo VAV 2-13 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0201 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0207 dis:Bravo VAV 2-13 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0201 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0208 dis:Bravo VAV 2-13 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0201 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0209 dis:Bravo VAV 2-14 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:24.2MMBTU/h designHotWaterFlow:2.5gal/min designAirFlow:1450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-020a dis:Bravo VAV 2-14 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0209 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-020b dis:Bravo VAV 2-14 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0209 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-020c dis:Bravo VAV 2-14 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0209 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-020d dis:Bravo VAV 2-14 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-0209 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-020e dis:Bravo VAV 2-14 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0209 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-020f dis:Bravo VAV 2-14 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0209 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0210 dis:Bravo VAV 2-14 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0209 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0211 dis:Bravo VAV 2-15 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.7MMBTU/h designHotWaterFlow:1gal/min designAirFlow:400cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0212 dis:Bravo VAV 2-15 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0211 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0213 dis:Bravo VAV 2-15 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0211 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0214 dis:Bravo VAV 2-15 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0211 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0215 dis:Bravo VAV 2-15 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-0211 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0216 dis:Bravo VAV 2-15 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0211 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0217 dis:Bravo VAV 2-15 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0211 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0218 dis:Bravo VAV 2-15 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} equipRef:@b-0211 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0219 dis:Bravo VAV 2-16 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:400cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-021a dis:Bravo VAV 2-16 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0219 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-021b dis:Bravo VAV 2-16 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0219 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-021c dis:Bravo VAV 2-16 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0219 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-021d dis:Bravo VAV 2-16 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0219 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-021e dis:Bravo VAV 2-16 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0219 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-021f dis:Bravo VAV 2-16 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0219 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0220 dis:Bravo VAV 2-16 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0219 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0221 dis:Bravo VAV 2-17 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:8.9MMBTU/h designHotWaterFlow:1gal/min designAirFlow:400cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0222 dis:Bravo VAV 2-17 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0221 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0223 dis:Bravo VAV 2-17 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0221 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0224 dis:Bravo VAV 2-17 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0221 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0225 dis:Bravo VAV 2-17 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} equipRef:@b-0221 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0226 dis:Bravo VAV 2-17 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0221 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0227 dis:Bravo VAV 2-17 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0221 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0228 dis:Bravo VAV 2-17 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0221 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0229 dis:Bravo VAV 2-18 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:15MMBTU/h designHotWaterFlow:1.75gal/min designAirFlow:550cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-022a dis:Bravo VAV 2-18 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0229 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-022b dis:Bravo VAV 2-18 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0229 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-022c dis:Bravo VAV 2-18 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0229 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-022d dis:Bravo VAV 2-18 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0229 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-022e dis:Bravo VAV 2-18 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0229 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-022f dis:Bravo VAV 2-18 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0229 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0230 dis:Bravo VAV 2-18 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0229 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0231 dis:Bravo VAV 2-19 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:6.2MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:350cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0232 dis:Bravo VAV 2-19 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0231 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0233 dis:Bravo VAV 2-19 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0231 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0234 dis:Bravo VAV 2-19 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0231 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0235 dis:Bravo VAV 2-19 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0231 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0236 dis:Bravo VAV 2-19 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0231 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0237 dis:Bravo VAV 2-19 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0231 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0238 dis:Bravo VAV 2-19 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0231 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0239 dis:Bravo VAV 2-2 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.6MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:650cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-023a dis:Bravo VAV 2-2 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0239 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-023b dis:Bravo VAV 2-2 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0239 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-023c dis:Bravo VAV 2-2 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0239 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-023d dis:Bravo VAV 2-2 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0239 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-023e dis:Bravo VAV 2-2 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0239 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-023f dis:Bravo VAV 2-2 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0239 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0240 dis:Bravo VAV 2-2 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0239 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0241 dis:Bravo VAV 2-20 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:10.8MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:650cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0242 dis:Bravo VAV 2-20 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0241 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0243 dis:Bravo VAV 2-20 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0241 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0244 dis:Bravo VAV 2-20 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0241 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0245 dis:Bravo VAV 2-20 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0241 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0246 dis:Bravo VAV 2-20 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0241 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0247 dis:Bravo VAV 2-20 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0241 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0248 dis:Bravo VAV 2-20 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0241 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0249 dis:Bravo VAV 2-21 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:10.4MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:650cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-024a dis:Bravo VAV 2-21 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0249 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-024b dis:Bravo VAV 2-21 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0249 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-024c dis:Bravo VAV 2-21 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0249 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-024d dis:Bravo VAV 2-21 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0249 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-024e dis:Bravo VAV 2-21 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0249 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-024f dis:Bravo VAV 2-21 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0249 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0250 dis:Bravo VAV 2-21 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0249 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0251 dis:Bravo VAV 2-22 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0252 dis:Bravo VAV 2-22 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0251 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0253 dis:Bravo VAV 2-22 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0251 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0254 dis:Bravo VAV 2-22 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0251 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0255 dis:Bravo VAV 2-22 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-0251 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0256 dis:Bravo VAV 2-22 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0251 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0257 dis:Bravo VAV 2-22 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0251 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0258 dis:Bravo VAV 2-22 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0251 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0259 dis:Bravo VAV 2-23 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:148°F designHotWaterPower:6.2MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:350cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-025a dis:Bravo VAV 2-23 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0259 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-025b dis:Bravo VAV 2-23 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0259 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-025c dis:Bravo VAV 2-23 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0259 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-025d dis:Bravo VAV 2-23 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-0259 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-025e dis:Bravo VAV 2-23 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0259 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-025f dis:Bravo VAV 2-23 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0259 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0260 dis:Bravo VAV 2-23 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0259 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0261 dis:Bravo VAV 2-24 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:15.4MMBTU/h designHotWaterFlow:2.5gal/min designAirFlow:1600cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0262 dis:Bravo VAV 2-24 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0261 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0263 dis:Bravo VAV 2-24 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0261 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0264 dis:Bravo VAV 2-24 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0261 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0265 dis:Bravo VAV 2-24 Heating Valve cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0261 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0266 dis:Bravo VAV 2-24 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0261 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0267 dis:Bravo VAV 2-24 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0261 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0268 dis:Bravo VAV 2-24 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0261 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0269 dis:Bravo VAV 2-25 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:4.4MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:250cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-026a dis:Bravo VAV 2-25 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0269 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-026b dis:Bravo VAV 2-25 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0269 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-026c dis:Bravo VAV 2-25 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0269 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-026d dis:Bravo VAV 2-25 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0269 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-026e dis:Bravo VAV 2-25 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0269 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-026f dis:Bravo VAV 2-25 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0269 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0270 dis:Bravo VAV 2-25 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0269 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0271 dis:Bravo VAV 2-26 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:148°F designHotWaterPower:4.2MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:300cfm} equip hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0272 dis:Bravo VAV 2-26 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0271 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0273 dis:Bravo VAV 2-26 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0271 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0274 dis:Bravo VAV 2-26 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0271 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0275 dis:Bravo VAV 2-26 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0271 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0276 dis:Bravo VAV 2-26 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0271 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0277 dis:Bravo VAV 2-26 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-0271 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0278 dis:Bravo VAV 2-26 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0271 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0279 dis:Bravo VAV 2-27 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:148°F designHotWaterPower:18.6MMBTU/h designHotWaterFlow:2gal/min designAirFlow:1125cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-027a dis:Bravo VAV 2-27 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0279 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-027b dis:Bravo VAV 2-27 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0279 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-027c dis:Bravo VAV 2-27 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0279 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-027d dis:Bravo VAV 2-27 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0279 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-027e dis:Bravo VAV 2-27 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0279 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-027f dis:Bravo VAV 2-27 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} equipRef:@b-0279 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0280 dis:Bravo VAV 2-27 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0279 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0281 dis:Bravo VAV 2-28 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.5MMBTU/h designHotWaterFlow:1gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0282 dis:Bravo VAV 2-28 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0281 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0283 dis:Bravo VAV 2-28 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0281 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0284 dis:Bravo VAV 2-28 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0281 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0285 dis:Bravo VAV 2-28 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0281 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0286 dis:Bravo VAV 2-28 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0281 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0287 dis:Bravo VAV 2-28 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0281 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0288 dis:Bravo VAV 2-28 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0281 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0289 dis:Bravo VAV 2-29 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.8MMBTU/h designHotWaterFlow:1gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-028a dis:Bravo VAV 2-29 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0289 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-028b dis:Bravo VAV 2-29 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0289 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-028c dis:Bravo VAV 2-29 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0289 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-028d dis:Bravo VAV 2-29 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0289 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-028e dis:Bravo VAV 2-29 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0289 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-028f dis:Bravo VAV 2-29 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0289 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0290 dis:Bravo VAV 2-29 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0289 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0291 dis:Bravo VAV 2-3 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0292 dis:Bravo VAV 2-3 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0291 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0293 dis:Bravo VAV 2-3 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0291 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0294 dis:Bravo VAV 2-3 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0291 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0295 dis:Bravo VAV 2-3 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0291 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0296 dis:Bravo VAV 2-3 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0291 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0297 dis:Bravo VAV 2-3 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-0291 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0298 dis:Bravo VAV 2-3 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0291 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0299 dis:Bravo VAV 2-30 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.5MMBTU/h designHotWaterFlow:1gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-029a dis:Bravo VAV 2-30 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0299 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-029b dis:Bravo VAV 2-30 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0299 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-029c dis:Bravo VAV 2-30 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0299 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-029d dis:Bravo VAV 2-30 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0299 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-029e dis:Bravo VAV 2-30 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0299 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-029f dis:Bravo VAV 2-30 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0299 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02a0 dis:Bravo VAV 2-30 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0299 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02a1 dis:Bravo VAV 2-31 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:18.6MMBTU/h designHotWaterFlow:2gal/min designAirFlow:650cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02a2 dis:Bravo VAV 2-31 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02a1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02a3 dis:Bravo VAV 2-31 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02a1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02a4 dis:Bravo VAV 2-31 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02a1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02a5 dis:Bravo VAV 2-31 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-02a1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02a6 dis:Bravo VAV 2-31 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02a1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02a7 dis:Bravo VAV 2-31 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} equipRef:@b-02a1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02a8 dis:Bravo VAV 2-31 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-02a1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02a9 dis:Bravo VAV 2-32 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:28.6MMBTU/h designHotWaterFlow:3.5gal/min designAirFlow:2150cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02aa dis:Bravo VAV 2-32 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02a9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02ab dis:Bravo VAV 2-32 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02a9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02ac dis:Bravo VAV 2-32 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02a9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02ad dis:Bravo VAV 2-32 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-02a9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02ae dis:Bravo VAV 2-32 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02a9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02af dis:Bravo VAV 2-32 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-02a9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02b0 dis:Bravo VAV 2-32 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-02a9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02b1 dis:Bravo VAV 2-33 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:148°F designHotWaterPower:3.1MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:200cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02b2 dis:Bravo VAV 2-33 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02b1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02b3 dis:Bravo VAV 2-33 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02b1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02b4 dis:Bravo VAV 2-33 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02b1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02b5 dis:Bravo VAV 2-33 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-02b1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02b6 dis:Bravo VAV 2-33 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02b1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02b7 dis:Bravo VAV 2-33 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-02b1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02b8 dis:Bravo VAV 2-33 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-02b1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02b9 dis:Bravo VAV 2-34 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:10.3MMBTU/h designHotWaterFlow:1gal/min designAirFlow:575cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02ba dis:Bravo VAV 2-34 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02b9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02bb dis:Bravo VAV 2-34 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02b9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02bc dis:Bravo VAV 2-34 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02b9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02bd dis:Bravo VAV 2-34 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-02b9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02be dis:Bravo VAV 2-34 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02b9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02bf dis:Bravo VAV 2-34 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-02b9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02c0 dis:Bravo VAV 2-34 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-02b9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02c1 dis:Bravo VAV 2-35 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:148°F designHotWaterPower:3.1MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:250cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02c2 dis:Bravo VAV 2-35 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02c1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02c3 dis:Bravo VAV 2-35 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02c1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02c4 dis:Bravo VAV 2-35 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02c1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02c5 dis:Bravo VAV 2-35 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-02c1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02c6 dis:Bravo VAV 2-35 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02c1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02c7 dis:Bravo VAV 2-35 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-02c1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02c8 dis:Bravo VAV 2-35 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-02c1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02c9 dis:Bravo VAV 2-36 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02ca dis:Bravo VAV 2-36 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02c9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02cb dis:Bravo VAV 2-36 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02c9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02cc dis:Bravo VAV 2-36 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02c9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02cd dis:Bravo VAV 2-36 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-02c9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02ce dis:Bravo VAV 2-36 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02c9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02cf dis:Bravo VAV 2-36 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-02c9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02d0 dis:Bravo VAV 2-36 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-02c9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02d1 dis:Bravo VAV 2-37 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:10.5MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02d2 dis:Bravo VAV 2-37 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02d1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02d3 dis:Bravo VAV 2-37 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02d1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02d4 dis:Bravo VAV 2-37 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02d1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02d5 dis:Bravo VAV 2-37 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-02d1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02d6 dis:Bravo VAV 2-37 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02d1 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02d7 dis:Bravo VAV 2-37 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-02d1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02d8 dis:Bravo VAV 2-37 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-02d1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02d9 dis:Bravo VAV 2-38 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:148°F designHotWaterPower:4.9MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:250cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02da dis:Bravo VAV 2-38 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02d9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02db dis:Bravo VAV 2-38 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02d9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02dc dis:Bravo VAV 2-38 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02d9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02dd dis:Bravo VAV 2-38 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-02d9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02de dis:Bravo VAV 2-38 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02d9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02df dis:Bravo VAV 2-38 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-02d9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02e0 dis:Bravo VAV 2-38 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-02d9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02e1 dis:Bravo VAV 2-39 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.5MMBTU/h designHotWaterFlow:9.5gal/min designAirFlow:475cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02e2 dis:Bravo VAV 2-39 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02e1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02e3 dis:Bravo VAV 2-39 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02e1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02e4 dis:Bravo VAV 2-39 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02e1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02e5 dis:Bravo VAV 2-39 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-02e1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02e6 dis:Bravo VAV 2-39 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02e1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02e7 dis:Bravo VAV 2-39 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-02e1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02e8 dis:Bravo VAV 2-39 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-02e1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02e9 dis:Bravo VAV 2-4 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:2.9MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:150cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02ea dis:Bravo VAV 2-4 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02e9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02eb dis:Bravo VAV 2-4 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02e9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02ec dis:Bravo VAV 2-4 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02e9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02ed dis:Bravo VAV 2-4 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-02e9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02ee dis:Bravo VAV 2-4 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02e9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02ef dis:Bravo VAV 2-4 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-02e9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02f0 dis:Bravo VAV 2-4 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-02e9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02f1 dis:Bravo VAV 2-40 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.8MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:475cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02f2 dis:Bravo VAV 2-40 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02f1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02f3 dis:Bravo VAV 2-40 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02f1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02f4 dis:Bravo VAV 2-40 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02f1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02f5 dis:Bravo VAV 2-40 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-02f1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02f6 dis:Bravo VAV 2-40 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02f1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02f7 dis:Bravo VAV 2-40 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-02f1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02f8 dis:Bravo VAV 2-40 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-02f1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-02f9 dis:Bravo VAV 2-41 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.5MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:475cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-02fa dis:Bravo VAV 2-41 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.626-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-02f9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-02fb dis:Bravo VAV 2-41 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02f9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02fc dis:Bravo VAV 2-41 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-02f9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-02fd dis:Bravo VAV 2-41 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-02f9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-02fe dis:Bravo VAV 2-41 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-02f9 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-02ff dis:Bravo VAV 2-41 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-02f9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0300 dis:Bravo VAV 2-41 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-02f9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0301 dis:Bravo VAV 2-42 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:8.9MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0302 dis:Bravo VAV 2-42 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0301 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0303 dis:Bravo VAV 2-42 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0301 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0304 dis:Bravo VAV 2-42 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0301 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0305 dis:Bravo VAV 2-42 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0301 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0306 dis:Bravo VAV 2-42 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0301 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0307 dis:Bravo VAV 2-42 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0301 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0308 dis:Bravo VAV 2-42 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0301 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0309 dis:Bravo VAV 2-43 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:141°F designHotWaterPower:4.7MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:350cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-030a dis:Bravo VAV 2-43 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0309 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-030b dis:Bravo VAV 2-43 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0309 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-030c dis:Bravo VAV 2-43 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0309 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-030d dis:Bravo VAV 2-43 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0309 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-030e dis:Bravo VAV 2-43 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0309 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-030f dis:Bravo VAV 2-43 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0309 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0310 dis:Bravo VAV 2-43 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0309 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0311 dis:Bravo VAV 2-44 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.2MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0312 dis:Bravo VAV 2-44 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0311 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0313 dis:Bravo VAV 2-44 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0311 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0314 dis:Bravo VAV 2-44 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0311 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0315 dis:Bravo VAV 2-44 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0311 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0316 dis:Bravo VAV 2-44 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0311 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0317 dis:Bravo VAV 2-44 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0311 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0318 dis:Bravo VAV 2-44 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0311 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0319 dis:Bravo VAV 2-45 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:17.8MMBTU/h designHotWaterFlow:1.75gal/min designAirFlow:600cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-031a dis:Bravo VAV 2-45 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0319 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-031b dis:Bravo VAV 2-45 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0319 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-031c dis:Bravo VAV 2-45 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0319 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-031d dis:Bravo VAV 2-45 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0319 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-031e dis:Bravo VAV 2-45 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0319 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-031f dis:Bravo VAV 2-45 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0319 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0320 dis:Bravo VAV 2-45 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-0319 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0321 dis:Bravo VAV 2-46 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.8MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:475cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0322 dis:Bravo VAV 2-46 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0321 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0323 dis:Bravo VAV 2-46 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0321 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0324 dis:Bravo VAV 2-46 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0321 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0325 dis:Bravo VAV 2-46 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0321 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0326 dis:Bravo VAV 2-46 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0321 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0327 dis:Bravo VAV 2-46 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0321 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0328 dis:Bravo VAV 2-46 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0321 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0329 dis:Bravo VAV 2-47 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:25.9MMBTU/h designHotWaterFlow:2.5gal/min designAirFlow:1400cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-032a dis:Bravo VAV 2-47 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0329 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-032b dis:Bravo VAV 2-47 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0329 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-032c dis:Bravo VAV 2-47 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0329 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-032d dis:Bravo VAV 2-47 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0329 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-032e dis:Bravo VAV 2-47 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0329 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-032f dis:Bravo VAV 2-47 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0329 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0330 dis:Bravo VAV 2-47 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0329 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0331 dis:Bravo VAV 2-48 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.5MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:475cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0332 dis:Bravo VAV 2-48 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0331 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0333 dis:Bravo VAV 2-48 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0331 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0334 dis:Bravo VAV 2-48 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0331 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0335 dis:Bravo VAV 2-48 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0331 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0336 dis:Bravo VAV 2-48 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0331 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0337 dis:Bravo VAV 2-48 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0331 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0338 dis:Bravo VAV 2-48 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0331 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0339 dis:Bravo VAV 2-49 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.5MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:475cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-033a dis:Bravo VAV 2-49 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0339 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-033b dis:Bravo VAV 2-49 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0339 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-033c dis:Bravo VAV 2-49 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0339 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-033d dis:Bravo VAV 2-49 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0339 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-033e dis:Bravo VAV 2-49 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0339 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-033f dis:Bravo VAV 2-49 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-0339 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0340 dis:Bravo VAV 2-49 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-0339 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0341 dis:Bravo VAV 2-5 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:3.1MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:200cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0342 dis:Bravo VAV 2-5 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0341 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0343 dis:Bravo VAV 2-5 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0341 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0344 dis:Bravo VAV 2-5 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0341 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0345 dis:Bravo VAV 2-5 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-0341 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0346 dis:Bravo VAV 2-5 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0341 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0347 dis:Bravo VAV 2-5 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0341 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0348 dis:Bravo VAV 2-5 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-0341 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0349 dis:Bravo VAV 2-50 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:9.8MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:475cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-034a dis:Bravo VAV 2-50 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0349 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-034b dis:Bravo VAV 2-50 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0349 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-034c dis:Bravo VAV 2-50 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0349 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-034d dis:Bravo VAV 2-50 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0349 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-034e dis:Bravo VAV 2-50 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0349 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-034f dis:Bravo VAV 2-50 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0349 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0350 dis:Bravo VAV 2-50 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0349 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0351 dis:Bravo VAV 2-6 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:148°F designHotWaterPower:4.7MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:350cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0352 dis:Bravo VAV 2-6 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0351 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0353 dis:Bravo VAV 2-6 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0351 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0354 dis:Bravo VAV 2-6 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0351 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0355 dis:Bravo VAV 2-6 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0351 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0356 dis:Bravo VAV 2-6 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0351 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0357 dis:Bravo VAV 2-6 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0351 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0358 dis:Bravo VAV 2-6 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0351 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0359 dis:Bravo VAV 2-7 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:10MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:650cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-035a dis:Bravo VAV 2-7 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0359 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-035b dis:Bravo VAV 2-7 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0359 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-035c dis:Bravo VAV 2-7 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0359 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-035d dis:Bravo VAV 2-7 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0359 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-035e dis:Bravo VAV 2-7 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0359 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-035f dis:Bravo VAV 2-7 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0359 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0360 dis:Bravo VAV 2-7 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0359 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0361 dis:Bravo VAV 2-8 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:4.1MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0362 dis:Bravo VAV 2-8 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0361 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0363 dis:Bravo VAV 2-8 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0361 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0364 dis:Bravo VAV 2-8 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0361 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0365 dis:Bravo VAV 2-8 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-0361 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0366 dis:Bravo VAV 2-8 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York pointType:"" inScope backgroundPoint} discharge equipRef:@b-0361 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0367 dis:Bravo VAV 2-8 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0361 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0368 dis:Bravo VAV 2-8 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-0361 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0369 dis:Bravo VAV 2-9 airRef:@b-00ce custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:8.9MMBTU/h designHotWaterFlow:1gal/min designAirFlow:450cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-036a dis:Bravo VAV 2-9 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0369 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-036b dis:Bravo VAV 2-9 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0369 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-036c dis:Bravo VAV 2-9 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0369 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-036d dis:Bravo VAV 2-9 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0369 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-036e dis:Bravo VAV 2-9 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0369 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-036f dis:Bravo VAV 2-9 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0369 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0370 dis:Bravo VAV 2-9 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-0369 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0371 dis:Bravo VAV 3-1 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:14.1MMBTU/h designHotWaterFlow:2.5gal/min designAirFlow:1300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0372 dis:Bravo VAV 3-1 Air Damper Command air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York pointType:"" inScope backgroundPoint} damper discharge equipRef:@b-0371 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0373 dis:Bravo VAV 3-1 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0371 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0374 dis:Bravo VAV 3-1 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0371 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0375 dis:Bravo VAV 3-1 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0371 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0376 dis:Bravo VAV 3-1 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0371 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0377 dis:Bravo VAV 3-1 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0371 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0378 dis:Bravo VAV 3-1 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0371 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0379 dis:Bravo VAV 3-10 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:7.3MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:350cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-037a dis:Bravo VAV 3-10 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0379 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-037b dis:Bravo VAV 3-10 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0379 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-037c dis:Bravo VAV 3-10 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0379 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-037d dis:Bravo VAV 3-10 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-0379 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-037e dis:Bravo VAV 3-10 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0379 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-037f dis:Bravo VAV 3-10 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0379 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0380 dis:Bravo VAV 3-10 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0379 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0381 dis:Bravo VAV 3-11 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:22.7MMBTU/h designHotWaterFlow:2.25gal/min designAirFlow:1100cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0382 dis:Bravo VAV 3-11 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0381 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0383 dis:Bravo VAV 3-11 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0381 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0384 dis:Bravo VAV 3-11 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0381 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0385 dis:Bravo VAV 3-11 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-0381 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0386 dis:Bravo VAV 3-11 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0381 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0387 dis:Bravo VAV 3-11 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-0381 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0388 dis:Bravo VAV 3-11 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0381 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0389 dis:Bravo VAV 3-12 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:9.8MMBTU/h designHotWaterFlow:1.5gal/min designAirFlow:1000cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-038a dis:Bravo VAV 3-12 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0389 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-038b dis:Bravo VAV 3-12 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0389 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-038c dis:Bravo VAV 3-12 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0389 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-038d dis:Bravo VAV 3-12 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} equipRef:@b-0389 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-038e dis:Bravo VAV 3-12 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0389 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-038f dis:Bravo VAV 3-12 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0389 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0390 dis:Bravo VAV 3-12 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0389 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0391 dis:Bravo VAV 3-13 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:5.3MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:350cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0392 dis:Bravo VAV 3-13 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0391 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0393 dis:Bravo VAV 3-13 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0391 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0394 dis:Bravo VAV 3-13 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0391 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0395 dis:Bravo VAV 3-13 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-0391 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0396 dis:Bravo VAV 3-13 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0391 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0397 dis:Bravo VAV 3-13 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-0391 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0398 dis:Bravo VAV 3-13 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0391 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0399 dis:Bravo VAV 3-14 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:5.4MMBTU/h designHotWaterFlow:1gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-039a dis:Bravo VAV 3-14 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0399 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-039b dis:Bravo VAV 3-14 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0399 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-039c dis:Bravo VAV 3-14 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0399 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-039d dis:Bravo VAV 3-14 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0399 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-039e dis:Bravo VAV 3-14 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0399 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-039f dis:Bravo VAV 3-14 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0399 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03a0 dis:Bravo VAV 3-14 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-0399 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03a1 dis:Bravo VAV 3-15 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:147°F designHotWaterPower:2.7MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:250cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03a2 dis:Bravo VAV 3-15 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03a1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03a3 dis:Bravo VAV 3-15 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03a1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03a4 dis:Bravo VAV 3-15 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03a1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03a5 dis:Bravo VAV 3-15 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} equipRef:@b-03a1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03a6 dis:Bravo VAV 3-15 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03a1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03a7 dis:Bravo VAV 3-15 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-03a1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03a8 dis:Bravo VAV 3-15 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-03a1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03a9 dis:Bravo VAV 3-16 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:3.3MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03aa dis:Bravo VAV 3-16 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03a9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03ab dis:Bravo VAV 3-16 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03a9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03ac dis:Bravo VAV 3-16 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03a9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03ad dis:Bravo VAV 3-16 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-03a9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03ae dis:Bravo VAV 3-16 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03a9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03af dis:Bravo VAV 3-16 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} equipRef:@b-03a9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03b0 dis:Bravo VAV 3-16 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-03a9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03b1 dis:Bravo VAV 3-17 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:3.3MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03b2 dis:Bravo VAV 3-17 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03b1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03b3 dis:Bravo VAV 3-17 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03b1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03b4 dis:Bravo VAV 3-17 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03b1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03b5 dis:Bravo VAV 3-17 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-03b1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03b6 dis:Bravo VAV 3-17 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03b1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03b7 dis:Bravo VAV 3-17 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-03b1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03b8 dis:Bravo VAV 3-17 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-03b1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03b9 dis:Bravo VAV 3-18 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:12.4MMBTU/h designHotWaterFlow:1.5gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03ba dis:Bravo VAV 3-18 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03b9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03bb dis:Bravo VAV 3-18 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03b9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03bc dis:Bravo VAV 3-18 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03b9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03bd dis:Bravo VAV 3-18 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-03b9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03be dis:Bravo VAV 3-18 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03b9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03bf dis:Bravo VAV 3-18 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-03b9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03c0 dis:Bravo VAV 3-18 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-03b9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03c1 dis:Bravo VAV 3-19 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:155°F designHotWaterPower:2.1MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:150cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03c2 dis:Bravo VAV 3-19 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03c1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03c3 dis:Bravo VAV 3-19 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03c1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03c4 dis:Bravo VAV 3-19 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03c1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03c5 dis:Bravo VAV 3-19 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York inScope backgroundPoint} equipRef:@b-03c1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03c6 dis:Bravo VAV 3-19 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03c1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03c7 dis:Bravo VAV 3-19 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-03c1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03c8 dis:Bravo VAV 3-19 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-03c1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03c9 dis:Bravo VAV 3-2 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:8.7MMBTU/h designHotWaterFlow:1.5gal/min designAirFlow:800cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03ca dis:Bravo VAV 3-2 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03c9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03cb dis:Bravo VAV 3-2 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03c9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03cc dis:Bravo VAV 3-2 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03c9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03cd dis:Bravo VAV 3-2 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-03c9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03ce dis:Bravo VAV 3-2 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03c9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03cf dis:Bravo VAV 3-2 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-03c9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03d0 dis:Bravo VAV 3-2 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-03c9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03d1 dis:Bravo VAV 3-20 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:4.1MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03d2 dis:Bravo VAV 3-20 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03d1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03d3 dis:Bravo VAV 3-20 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03d1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03d4 dis:Bravo VAV 3-20 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03d1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03d5 dis:Bravo VAV 3-20 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-03d1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03d6 dis:Bravo VAV 3-20 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03d1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03d7 dis:Bravo VAV 3-20 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-03d1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03d8 dis:Bravo VAV 3-20 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-03d1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03d9 dis:Bravo VAV 3-21 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:6.5MMBTU/h designHotWaterFlow:1gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03da dis:Bravo VAV 3-21 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03d9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03db dis:Bravo VAV 3-21 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:11.258-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03d9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03dc dis:Bravo VAV 3-21 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03d9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03dd dis:Bravo VAV 3-21 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} equipRef:@b-03d9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03de dis:Bravo VAV 3-21 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03d9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03df dis:Bravo VAV 3-21 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-03d9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03e0 dis:Bravo VAV 3-21 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} equipRef:@b-03d9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03e1 dis:Bravo VAV 3-22 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:29.2MMBTU/h designHotWaterFlow:3.5gal/min designAirFlow:1250cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03e2 dis:Bravo VAV 3-22 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03e1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03e3 dis:Bravo VAV 3-22 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03e1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03e4 dis:Bravo VAV 3-22 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03e1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03e5 dis:Bravo VAV 3-22 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} equipRef:@b-03e1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03e6 dis:Bravo VAV 3-22 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03e1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03e7 dis:Bravo VAV 3-22 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} equipRef:@b-03e1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03e8 dis:Bravo VAV 3-22 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-03e1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03e9 dis:Bravo VAV 3-23 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:2.2MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:200cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03ea dis:Bravo VAV 3-23 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York pointType:"" inScope backgroundPoint} damper discharge equipRef:@b-03e9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03eb dis:Bravo VAV 3-23 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03e9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03ec dis:Bravo VAV 3-23 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03e9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03ed dis:Bravo VAV 3-23 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-03e9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03ee dis:Bravo VAV 3-23 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03e9 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03ef dis:Bravo VAV 3-23 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York inScope backgroundPoint} equipRef:@b-03e9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03f0 dis:Bravo VAV 3-23 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York inScope backgroundPoint} equipRef:@b-03e9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03f1 dis:Bravo VAV 3-24 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:6.4MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03f2 dis:Bravo VAV 3-24 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03f1 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03f3 dis:Bravo VAV 3-24 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03f1 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03f4 dis:Bravo VAV 3-24 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03f1 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03f5 dis:Bravo VAV 3-24 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-03f1 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03f6 dis:Bravo VAV 3-24 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03f1 his kind:Str point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03f7 dis:Bravo VAV 3-24 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-03f1 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03f8 dis:Bravo VAV 3-24 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} equipRef:@b-03f1 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-03f9 dis:Bravo VAV 3-25 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:149°F designHotWaterPower:16.6MMBTU/h designHotWaterFlow:2gal/min designAirFlow:500cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-03fa dis:Bravo VAV 3-25 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-03f9 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-03fb dis:Bravo VAV 3-25 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03f9 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03fc dis:Bravo VAV 3-25 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-03f9 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-03fd dis:Bravo VAV 3-25 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-03f9 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-03fe dis:Bravo VAV 3-25 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:10.497-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-03f9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-03ff dis:Bravo VAV 3-25 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-03f9 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0400 dis:Bravo VAV 3-25 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-03f9 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0401 dis:Bravo VAV 3-26 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:12.9MMBTU/h designHotWaterFlow:1.5gal/min designAirFlow:400cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0402 dis:Bravo VAV 3-26 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0401 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0403 dis:Bravo VAV 3-26 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0401 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0404 dis:Bravo VAV 3-26 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0401 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0405 dis:Bravo VAV 3-26 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0401 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0406 dis:Bravo VAV 3-26 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0401 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0407 dis:Bravo VAV 3-26 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0401 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0408 dis:Bravo VAV 3-26 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} equipRef:@b-0401 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0409 dis:Bravo VAV 3-27 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:6MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-040a dis:Bravo VAV 3-27 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:07.473-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0409 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-040b dis:Bravo VAV 3-27 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:10.745-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0409 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-040c dis:Bravo VAV 3-27 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0409 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-040d dis:Bravo VAV 3-27 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} equipRef:@b-0409 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-040e dis:Bravo VAV 3-27 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York pointType:"" inScope backgroundPoint} discharge equipRef:@b-0409 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-040f dis:Bravo VAV 3-27 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0409 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0410 dis:Bravo VAV 3-27 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:10.62-04:00 New_York inScope backgroundPoint} equipRef:@b-0409 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0411 dis:Bravo VAV 3-28 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:3MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:200cfm} equip fanPowered hotWaterHeating hotWaterRef:@b-0012 hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e thermostat vav zone --- id:@b-0412 dis:Bravo VAV 3-28 Damper Output air cmd cur custom:{sourcePointName:"DAMPER_CMD" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} damper discharge equipRef:@b-0411 his kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" --- id:@b-0413 dis:Bravo VAV 3-28 Discharge Air Flow air cur custom:{sourcePointName:"BOX_FLOW" dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0411 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0414 dis:Bravo VAV 3-28 Discharge Air Flow Setpoint air cur custom:{sourcePointName:"FLOW_STPT" dataSyncRecovered:2020-07-10T01:00:10.995-04:00 New_York inScope backgroundPoint} discharge effective equipRef:@b-0411 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0415 dis:Bravo VAV 3-28 Heating Valve Output cmd cur custom:{sourcePointName:"Htg" dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York inScope backgroundPoint} equipRef:@b-0411 heat his hot kind:Number point siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:"%" valve water --- id:@b-0416 dis:Bravo VAV 3-28 Supply Air Temperature air cur custom:{sourcePointName:"DisAirTemp" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} discharge equipRef:@b-0411 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F --- id:@b-0417 dis:Bravo VAV 3-28 Zone Air Temp Setpoint air cur custom:{sourcePointName:"STAT_SETPOINT" dataSyncRecovered:2020-07-10T01:00:09.627-04:00 New_York inScope backgroundPoint} equipRef:@b-0411 his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0418 dis:Bravo VAV 3-28 Zone Temperature air cur custom:{sourcePointName:"SPACE_TEMP" dataSyncRecovered:2020-07-10T01:00:13.145-04:00 New_York inScope backgroundPoint} equipRef:@b-0411 his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e temp tz:Chicago unit:°F zone --- id:@b-0419 dis:Bravo VAV 3-3 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:4.2MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:375cfm} equip hotWaterHeating hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e vav --- id:@b-041a dis:Bravo VAV 3-3 Supply Air Flow air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York backgroundPoint} discharge equipRef:@b-0419 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-041b dis:Bravo VAV 3-3 Supply Air Flow Setpoint air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York backgroundPoint} discharge equipRef:@b-0419 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-041c dis:Bravo VAV 3-4 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:155°F designHotWaterPower:1.7MMBTU/h designHotWaterFlow:0.5gal/min designAirFlow:150cfm} equip hotWaterHeating hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e vav --- id:@b-041d dis:Bravo VAV 3-4 Supply Air Flow air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:10.87-04:00 New_York backgroundPoint} discharge equipRef:@b-041c flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-041e dis:Bravo VAV 3-4 Supply Air Flow Setpoint air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:07.721-04:00 New_York backgroundPoint} discharge equipRef:@b-041c flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-041f dis:Bravo VAV 3-5 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:3.3MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip hotWaterHeating hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e vav --- id:@b-0420 dis:Bravo VAV 3-5 Supply Air Flow air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:11.125-04:00 New_York backgroundPoint} discharge equipRef:@b-041f flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0421 dis:Bravo VAV 3-5 Supply Air Flow Setpoint air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:09.752-04:00 New_York backgroundPoint} discharge equipRef:@b-041f flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0422 dis:Bravo VAV 3-6 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:152°F designHotWaterPower:6.5MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:600cfm} equip hotWaterHeating hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e vav --- id:@b-0423 dis:Bravo VAV 3-6 Supply Air Flow air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:10.003-04:00 New_York backgroundPoint} discharge equipRef:@b-0422 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0424 dis:Bravo VAV 3-6 Supply Air Flow Setpoint air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York backgroundPoint} discharge equipRef:@b-0422 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0425 dis:Bravo VAV 3-7 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:150°F designHotWaterPower:7.6MMBTU/h designHotWaterFlow:1.25gal/min designAirFlow:700cfm} equip hotWaterHeating hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e vav --- id:@b-0426 dis:Bravo VAV 3-7 Supply Air Flow air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York backgroundPoint} discharge equipRef:@b-0425 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0427 dis:Bravo VAV 3-7 Supply Air Flow Setpoint air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:10.249-04:00 New_York backgroundPoint} discharge equipRef:@b-0425 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-0428 dis:Bravo VAV 3-8 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:153°F designHotWaterPower:6.5MMBTU/h designHotWaterFlow:0.75gal/min designAirFlow:300cfm} equip hotWaterHeating hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e vav --- id:@b-0429 dis:Bravo VAV 3-8 Supply Air Flow air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:07.598-04:00 New_York backgroundPoint} discharge equipRef:@b-0428 flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-042a dis:Bravo VAV 3-8 Supply Air Flow Setpoint air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:10.374-04:00 New_York backgroundPoint} discharge equipRef:@b-0428 flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-042b dis:Bravo VAV 3-9 airRef:@b-00f2 custom:{tu designSource:"Drawings" designHotWaterEnteringTemp:180°F designHotWaterLeavingTemp:151°F designHotWaterPower:23MMBTU/h designHotWaterFlow:4gal/min designAirFlow:2000cfm} equip hotWaterHeating hvac singleDuct siteRef:@b-0000 spaceRef:@b-042e vav --- id:@b-042c dis:Bravo VAV 3-9 Supply Air Flow air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:09.879-04:00 New_York backgroundPoint} discharge equipRef:@b-042b flow his kind:Number point sensor siteRef:@b-0000 spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-042d dis:Bravo VAV 3-9 Supply Air Flow Setpoint air cur custom:{dateCreated:2020-04-03 dataSyncRecovered:2020-07-10T01:00:10.126-04:00 New_York backgroundPoint} discharge equipRef:@b-042b flow his kind:Number point siteRef:@b-0000 sp spaceRef:@b-042e tz:Chicago unit:cfm --- id:@b-042e dis:Bravo VAVs custom:{equipType} siteRef:@b-0000 space --- id:@b-042f dis:"Fort Wayne, IN" geoCity:Fort Wayne geoCoord:C(41.131,-85.129) geoCountry:US geoState:IN tz:Indianapolis weatherStation --- id:@b-0430 dis:"Fort Wayne, IN Condition" enum:"unknown,clear,partlyCloudy,cloudy,showers,rain,thunderstorms,ice,flurries,snow" his kind:Str point sensor tz:Indianapolis weather weatherCond weatherStationRef:@b-042f --- id:@b-0431 dis:"Fort Wayne, IN Humidity" air his humidity kind:Number point sensor tz:Indianapolis unit:"%RH" weather weatherStationRef:@b-042f --- id:@b-0432 dis:"Fort Wayne, IN Sunrise" daytime his kind:Bool point sensor tz:Indianapolis weather weatherStationRef:@b-042f --- id:@b-0433 dis:"Fort Wayne, IN Temp" air his kind:Number point sensor temp tz:Indianapolis unit:°F weather weatherStationRef:@b-042f --- id:@b-0434 dis:Points Not Syncing custom:{diagnostics dataSync dataSyncRecovered:2020-07-14T01:00:05.167-04:00 New_York backgroundPoint} his kind:Number point sensor siteRef:@b-0000 tz:Chicago